Thyratron
Other
Peak forward anode voltage
1500 V
Peak inverse anode voltage
1500 V
Peak cathode/anode current
30 A
Average cathode/anode current
2.5 A
Fault or surge current
250 A
ShortDuration
Ambient temperature range
-40 to +90 C
Filament voltage
2.5 V
Filament current
9 A
Characteristic
Ionization time
10 us
Approximate
Deionization time
1000 us
Approximate
Anode voltage drop
10 V
Conducting
Minimum heating time
20 s
BeforeConduction
Condensed-mercury temperature rise no load
25 degC
Condensed-mercury temperature rise full load
30 degC
Construction
Gas fill
Gas and mercury vapor
Capacitance
Grid-to-anode capacitance
2 pF
Approximate
Grid-to-cathode capacitance
12 pF
Approximate