Skip to main content

Specialized - Magnetron ·Magnetron

7091

Forced-air-cooled continuous-wave magnetron for industrial generators and microwave ovens near 2.45 GHz, with kilowatt-class output.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
5 V / 35 A

Description

A forced-air-cooled continuous-wave magnetron for industrial generators and microwave ovens around 2450 Mc/s, with kilowatt-class output.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
5 V
Nominal heater current
35 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Magnetron

X-ray radiationInterelectrode capacitances

No fixed ratings are recorded for this section.

Magnetron section; canonical SectionType fallback Other.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1999 Philips 0-D

Published operating points and test conditions from this source.

SECTION 1

Magnetron

Characteristics

  • Frequency nominal

    2450 Mc/s

  • Frequency tolerance

    25 Mc/s

  • Heater voltage

    5 V

  • Heater current

    35 A

  • Cathode heating time minimum

    2 min

  • Anode current Iy

    750 mA

    PublishedLine: Anode current Iy = 750 mA

  • Anode voltage Va

    0.2 kV

    PublishedLine: Anode voltage Va = 4.6 + 0,2 kV

  • sortie de

    2.5 kW

    PublishedLine: sortie de 2,5 kW, il est recommandg de prendre la tension

  • A. OPERATION WITH

    2.5 kW

    PublishedLine: A. OPERATION WITH 2.5 kW OUTPUT POWER (continued)

  • Qutput power Yo

    2.5 kW

    PublishedLine: Qutput power Yo = 2.5 kW 9)

  • B. OPERATION WITH

    2 kW

    PublishedLine: B. OPERATION WITH 2.0 kW QUTPUT POWER

Other

  • CW output power

    2.5 kW

  • une fr quence fixe de

    25 MHz

    PublishedLine: une fréquence fixe de 2450 % 25 MHz et peut fournir des

  • pulssances de

    2.5 kW

    PublishedLine: pulssances de 2 ou de 2,5 kW dépendant des taux d'ondes

  • Frequenz von

    25 MHz

    PublishedLine: Frequenz von 2450 * 25 MHz und kann, abhiZngig vom Re-

  • flexionsbereich eine Ausgangsleistung von

    2.5 kW

    PublishedLine: flexionsbereich, eine Ausgangsleistung von 2 oder 2,5 kW

  • It operates at a fixed frequency of

    25 Mc/s

    PublishedLine: It operates at a fixed frequency of 2450 * 25 Mc/s and is

  • tinuous wave output power levels of

    2 kW

    PublishedLine: tinuous wave output power levels of 2 kW and 2.5 kW, these

  • specified for the

    2 kW

    PublishedLine: specified for the 2 kW operation.

  • Die Rohre ist fur die Kopplung an ein

    50 Ohm

    PublishedLine: Die Rohre ist fur die Kopplung an ein 50 Ohm-Koaxialkabel

  • A. OPERATION WITH

    2.5 kW

    PublishedLine: A. OPERATION WITH 2.5 kW OU- -UT POWER

  • Anode voltage Va

    4.6 kv

    PublishedLine: Anode voltage Va = 4.6 kv 4)5)

  • output power W

    2 kW

    PublishedLine: output power W = 2.0 kW 3)

  • Column A For operation with

    2.5 kW

    PublishedLine: Column A: For operation with 2.5 kW output power 1)