Data set 01
1937 Ken Rad
Published operating points and test conditions from this source.
Rectifier
Characteristics
Plate Voltage
350 V
AC Plate Voltage (RMS per plate) 350 Volts Max.
Load Current
100 mA
Load Current 100 Milliamperes Max.
Rectifier - Full Wave ·Rectifier-Rectifier
Indirectly heated full-wave high-vacuum rectifier for AC power supplies. Rated for approximately 1.25 kV peak inverse voltage and 100 mA DC output from a 6.3 V heater.
Full-wave high-vacuum rectifier with a 6.3 V, 0.9 A heater.
International Octal
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
| Terminal | Section | Connection | Evidence |
|---|---|---|---|
| PIN1IS | A | IS — Internal Screen EIA chart transcription; independent manufacturer verification pending | Unverified EIA Base Connections, printed page 127, 6S |
| PIN2H | — | H — Heater EIA chart transcription; independent manufacturer verification pending | Unverified EIA Base Connections, printed page 127, 6S |
| PIN32P | A | P — Plate (Anode) EIA chart transcription; independent manufacturer verification pending | Unverified EIA Base Connections, printed page 127, 6S |
| PIN51P | A | P — Plate (Anode) EIA chart transcription; independent manufacturer verification pending | Unverified EIA Base Connections, printed page 127, 6S |
| PIN7H | — | H — Heater EIA chart transcription; independent manufacturer verification pending | Unverified EIA Base Connections, printed page 127, 6S |
| PIN8K | A | K — Cathode EIA chart transcription; independent manufacturer verification pending | Unverified EIA Base Connections, printed page 127, 6S |
2 physical sections, each with unique specifications.
Section 1
Source-defined physical/function section.
Section 2
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Plate Voltage
350 V
AC Plate Voltage (RMS per plate) 350 Volts Max.
Load Current
100 mA
Load Current 100 Milliamperes Max.
Data set 02
Published operating points and test conditions from this source.
Heater voltage
6.3 V
Section1
Heater current
900 mA
Section1
RMS AC voltage per plate maximum
350 V
FullWave
DC output current maximum
100 mA
FullWave
Maximum heater-cathode DC voltage
500 V
FullWave
Data set 03
Published operating points and test conditions from this source.
Maximum peak inverse voltage
1250 V
Nominal DC output current
90 mA
Maximum peak forward current
270 mA
Maximum RMS supply voltage
325 V
Forward voltage drop
24 V
Forward-voltage-drop test current
90 mA