Skip to main content

Voltage - Triode (with diode, heptode or hexode) ·Diode-Diode-Triode-Triode

6V8

Miniature triple-diode high-mu triode combining multiple detector or control-voltage rectifier sections with a voltage-amplifier triode for receiver signal processing.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
4
Base
-
Socket code
B9A
Base pins
-
Nominal heater
6.3 V / 450 mA

Description

Triple-diode high-mu triode miniature tube.

Socket description

Small-button Noval 9-contact

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
B9A
Base pins
-
Nominal heater voltage
6.3 V
Nominal heater current
450 mA
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

4 physical sections, each with unique specifications.

Section 1

Diode

X-ray radiationInterelectrode capacitances

No fixed ratings are recorded for this section.

Representative row for identical repeated sections.

Section 2

Triode

X-ray radiationInterelectrode capacitances
Plate resistance
48000 Ω
Transconductance
0.0012 S
Amplification factor
70
Max plate voltage
300 V
Max plate dissipation
1 W

Section 3

Diode

X-ray radiationInterelectrode capacitances

No fixed ratings are recorded for this section.

Second physical diode section; added to align rows with SectionCount.

Section 4

Triode

X-ray radiationInterelectrode capacitances
Plate resistance
48000 Ω
Transconductance
0.0012 S
Amplification factor
70
Max plate voltage
300 V
Max plate dissipation
1 W

Second physical triode section; added to align rows with SectionCount.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

No source-specific operating conditions are recorded.