Heater Warm-up Time (Average) —
11 s
Other
Peak value
200 V
Other;PublishedValue1
Peak value
200 V
Other;PublishedValue2
Peak value
200 V
Other;PublishedValue3
Average value
100 V
Other;PublishedValue1
Average value
100 V
Other;PublishedValue2
Average value
100 V
Other;PublishedValue3
Plate Voltage
350 V
MaximumRating
Grid-No
2 V
MaximumRating;PublishedValue1
Grid-No
315 V
MaximumRating;PublishedValue2
Plate Dissipation
14 W
MaximumRating
Grid-No
2 W
MaximumRating;PublishedValue1
Grid-No
2.2 W
MaximumRating;PublishedValue2
Plate Voltage
180 V
TypicalOperation;PublishedValue1
Plate Voltage
250 V
TypicalOperation;PublishedValue2
Plate Voltage
315 V
TypicalOperation;PublishedValue3
Grid-No
2 V
TypicalOperation;PublishedValue1
Grid-No
180 V
TypicalOperation;PublishedValue2
Grid-No
250 V
TypicalOperation;PublishedValue3
Grid-No
225 V
TypicalOperation;PublishedValue4
Peak AF Grid-No.l Voltage
-8.5 V
TypicalOperation;PublishedValue1
Peak AF Grid-No.l Voltage
12.5 V
TypicalOperation;PublishedValue2
Peak AF Grid-No.l Voltage
-13 V
TypicalOperation;PublishedValue3
Published value
8.5 V
TypicalOperation;PublishedValue1
Published value
12.5 V
TypicalOperation;PublishedValue2
Published value
13 V
TypicalOperation;PublishedValue3
Zero-Signal Plate Current
29 mA
TypicalOperation;PublishedValue1
Zero-Signal Plate Current
45 mA
TypicalOperation;PublishedValue2
Zero-Signal Plate Current
34 mA
TypicalOperation;PublishedValue3
Maximum-Signal Plate Current
30 mA
TypicalOperation;PublishedValue1
Maximum-Signal Plate Current
47 mA
TypicalOperation;PublishedValue2
Maximum-Signal Plate Current
35 mA
TypicalOperation;PublishedValue3
Zero-Signal Grid-No
2 mA
TypicalOperation;PublishedValue1
Zero-Signal Grid-No
3 mA
TypicalOperation;PublishedValue2
Zero-Signal Grid-No
4.5 mA
TypicalOperation;PublishedValue3
Zero-Signal Grid-No
2.2 mA
TypicalOperation;PublishedValue4
Maximum-Signal Grid-No
2 mA
TypicalOperation;PublishedValue1
Maximum-Signal Grid-No
4 mA
TypicalOperation;PublishedValue2
Maximum-Signal Grid-No
7 mA
TypicalOperation;PublishedValue3
Maximum-Signal Grid-No
6 mA
TypicalOperation;PublishedValue4
Plate Resistance (Approx.)
50000 ohm
TypicalOperation;PublishedValue1
Plate Resistance (Approx.)
50000 ohm
TypicalOperation;PublishedValue2
Plate Resistance (Approx.)
80000 ohm
TypicalOperation;PublishedValue3
Transconductance
3700 uS
TypicalOperation;PublishedValue1
Transconductance
4100 uS
TypicalOperation;PublishedValue2
Transconductance
3750 uS
TypicalOperation;PublishedValue3
Load Resistance
5500 ohm
TypicalOperation;PublishedValue1
Load Resistance
5000 ohm
TypicalOperation;PublishedValue2
Load Resistance
8500 ohm
TypicalOperation;PublishedValue3