Data set 01
1971 RCA HB3 Binder 2 of 7
Published operating points and test conditions from this source.
Thyratron
Characteristics
Voltage — published value 1
6.3 V
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
Voltage — published value 2
10 V
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
Current at 6.3 volts
6.3 V
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
Minimum
2 A
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
Average
2.3 A
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
Minimum heating time
2
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
Ionization Time (Approx.)°
0.6 s
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
Deionization Time (Approx )
25 s
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
at middle of pulse duration
150 V
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
DC ANODE-SUPPLY VOLTAGE
800 V
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
Inverse
5 V
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
Peak positive-pulse
175 V
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
AMBIENT-TEMPERATURE RANGE — published value 1
-50 C
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
AMBIENT-TEMPERATURE RANGE — published value 2
90 C
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
DC Anode-Supply Voltage
1250 V
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
Forward
3000 V
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
current pulse
530 V
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
Negative, before conduction
0 V
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
Peak positive-pulse (Unloaded)
175 V
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
Effective Grid-Circuit Resistance
1000 ohm
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
Peak
35 A
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
Average°
35 mA
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
amplitude and the point on the anode-current Dulse which is 26 Der cent
26 A
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
Of 0.05 µsec. The grid pulse ha5a minimum peak ampl itude of 130 volts, — published value 1
0.05 V
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
Of 0.05 µsec. The grid pulse ha5a minimum peak ampl itude of 130 volts, — published value 2
130 V
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
voltage Is applied at a rate not to exceed 75,000 volts per second — published value 1
75 V
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
voltage Is applied at a rate not to exceed 75,000 volts per second — published value 2
0 V
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
pulse envelope at which instantaneous amplitudes are equal to 70.7 per
70.7 A
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
j Operation with a bu1D temperature within the approximate range of 600
600
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
voltage of 175 volts (unloaded)
175 V
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
R1: Grid Resistor, 30,000 ohms — published value 1
30 ohm
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
R1: Grid Resistor, 30,000 ohms — published value 2
0 ohm
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
Ry: Effective Resistance of grid clr uit, 1000 ohms
1000 ohm
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
Heater or filament voltage nominal
6.3 V
Nominal value from supplied datasheet.
Heater or filament current nominal
2.3 A
Nominal or average value from supplied datasheet.
Other
Maximum
2.5 A
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
Forward (Ebmf)
3000 V
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
During first 25 µsec — published value 1
25 V
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
During first 25 µsec — published value 2
1500 V
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
After first 25 µsec — published value 1
25 V
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
After first 25 µsec — published value 2
3000 V
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
before conduction
200 V
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
Peak
35 mA
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
Average°
0.045 mA
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
Rate of rise
750 mA
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
Effective Grid-Circuit Resistance
1500 mA
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.
maximum internal impedance of 1500 ohms
1500 ohm
Published datasheet value; multiple values on one row represent separate limits, service ratings, or operating conditions.