Skip to main content

Voltage - Dual Triode (similar) ·Triode-Triode

6SN7WGTA

Premium ruggedized medium-mu twin triode for amplifiers, oscillators, and pulse circuits. Special-quality construction combines familiar 6SN7 electrical behavior with enhanced durability and voltage capability for demanding professional service.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
2
Base
8BD
Socket code
IO
Base pins
8
Nominal heater
6.3 V / 600 mA

Description

Premium medium-mu twin triode for amplifiers, oscillators, and pulse circuits. Data was extracted from the supplied Tung-Sol source, including published ratings, characteristics, and operating information.

Socket description

International Octal

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
8BD
Socket code
IO
Base pins
8
Nominal heater voltage
6.3 V
Nominal heater current
600 mA
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

8BD - Terminal pinout

Electrical assignments shared by every tube using this base designation.

TerminalSectionConnectionEvidence
PIN12G1BG1 — Control Grid

EIA transcription; manufacturer confirmation pending

Unverified

EIA Base Connections, printed page 129, 8BD

PIN22PBP — Plate (Anode)

EIA transcription; manufacturer confirmation pending

Unverified

EIA Base Connections, printed page 129, 8BD

PIN32KBK — Cathode

EIA transcription; manufacturer confirmation pending

Unverified

EIA Base Connections, printed page 129, 8BD

PIN41G1AG1 — Control Grid

EIA transcription; manufacturer confirmation pending

Unverified

EIA Base Connections, printed page 129, 8BD

PIN51PAP — Plate (Anode)

EIA transcription; manufacturer confirmation pending

Unverified

EIA Base Connections, printed page 129, 8BD

PIN61KAK — Cathode

EIA transcription; manufacturer confirmation pending

Unverified

EIA Base Connections, printed page 129, 8BD

PIN7H—H — Heater

EIA transcription; manufacturer confirmation pending

Unverified

EIA Base Connections, printed page 129, 8BD

PIN8H—H — Heater

EIA transcription; manufacturer confirmation pending

Unverified

EIA Base Connections, printed page 129, 8BD

Section ratings

2 physical sections, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Plate resistance
6700 Ω
Transconductance
0.003 S
Amplification factor
20
Max plate voltage
450 V
Max plate dissipation
5 W
Max cathode current
70 mA

Published promoted fields populated from printed headings; identical repeated sections compressed.

Section 2

Triode

X-ray radiationInterelectrode capacitances
Plate resistance
6700 Ω
Transconductance
0.003 S
Amplification factor
20
Max plate voltage
450 V
Max plate dissipation
5 W
Max cathode current
70 mA

Second identical physical section; added to align physical rows with SectionCount.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1961 Tung Sol

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristic

  • Plate Resistance

    7700 ohm

    AlternateOperatingPoint

  • Transconductance

    2600 uS

    AlternateOperatingPoint

Data set 02

1966 Tung Sol Electronic Tubes 3 of 4

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristics

  • Plate resistance

    6700 ohm

    PromotedValue

  • Transconductance

    0.003 A/V

    PromotedValue

  • Amplification factor

    20

    PromotedValue

  • NEATER VOLTAGE

    5 VOLTS

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • HEATER VOLTAGE

    6 VOLTS

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • PLATE VOLTAGE — published value 1

    9 VOLTS

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • PLATE VOLTAGE — published value 2

    2 VOLTS

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • PLATE CURRENT

    9 mA

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • AMPLIFICATION FACTOR

    2

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • PLATE RESISTANCE (APPROX .~) — published value 1

    7 OHMS

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • PLATE RESISTANCE (APPROX .~) — published value 2

    0 OHMS

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • TRANSCONDUCTANCE

    2 µMHOS

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • PLATE CURRENT (g E c =- 12,5 VOLTS

    12.5 VOLTS

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • GRID VOLTAGE FOR Ib = 10 j1A (APPROX.) — published value 1

    7 VOLTS

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • GRID VOLTAGE FOR Ib = 10 j1A (APPROX.) — published value 2

    1 VOLTS

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • 90 VOLTS — published value 1

    180 VOLTS

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • 90 VOLTS — published value 2

    300 VOLTS

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • GAIN MEASURED AT EO = 2.0 VOLTS RMS OUTPUT.

    2 VOLTS

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • HEATER CURRENT — published value 1

    550 ma

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • HEATER CURRENT — published value 2

    650 ma

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • GRID CURRENTA — published value 1

    -1.5

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • GRID CURRENTA — published value 2

    -1.5

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • PLATE CURRENT (i) — published value 1

    5.5 mAdc

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • PLATE CURRENT (i) — published value 2

    12.5 mAdc

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • AMPLIFICATION FACTOR E — published value 1

    18

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • AMPLIFICATION FACTOR E — published value 2

    23

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • (PRESSURE =55t5mm HG; VOLTAGE =SQQVac) — published value 1

    55

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • (PRESSURE =55t5mm HG; VOLTAGE =SQQVac) — published value 2

    5

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • PLATE CURRENT (2) — published value 1

    2

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • PLATE CURRENT (2) — published value 2

    15

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • TRANSCOND UCTANCE (i)

    1850

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

Other

  • Maximum plate voltage

    450 V

    PromotedValue

  • Maximum plate dissipation

    5 W

    PromotedValue

  • Maximum cathode current

    70 mA

    PromotedValue

  • MAXIMUM DC PLATE VOLTAGE

    0 VOLTS

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • MAXIMUM PLATE DISSIPATION (PER PLATE)

    44 WATTS

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • MAXIMUM GRID RESISTANCE

    1.1

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • MAXIMUM HEATER-CATHODE VOLTAGE

    2 VOLTS

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • MAXIMUM DC PLATE CURRENT (PER PLATE)

    20 mAdc

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • MAXIMUM BULB TEMPERATURE

    200

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.