Data set 01
1948 Brimar Radio Valve Manual
Published operating points and test conditions from this source.
Triode
Characteristic
Heater Voltage
6.3 V
Heater Current
300 mA
Voltage - Dual Triode (similar) ·Triode-Triode
High-mu twin triode for resistance-coupled voltage amplification and phase inversion, widely applicable to low-level Class-A signal stages.
High-mu twin triode used as a phase inverter and in resistance-coupled amplifier circuits. Explicit heater variant/co-designation of 12SL7GT in the approved source.
International Octal
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
2 physical sections, each with unique specifications.
Section 1
Representative row for each identical triode section.
Section 2
Second identical physical triode section; added to align rows with SectionCount.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Heater Voltage
6.3 V
Heater Current
300 mA
Data set 02
Published operating points and test conditions from this source.
Heater Voltage
6.3 V
Heater Current
300 mA
Data set 03
Published operating points and test conditions from this source.
Maximum plate voltage
300 V
Published handbook rating
Plate voltage
250 V
ClassA OperatingPoint1
Control-grid bias
2 V
ClassA OperatingPoint1
Plate current
2.3 mA
ClassA OperatingPoint1
Plate resistance
44000 ohm
ClassA OperatingPoint1
Transconductance
1600 µS
ClassA OperatingPoint1
Amplification factor
70
ClassA OperatingPoint1
Heater voltage
6.3 V
Published heater rating
Heater current
300 mA
Published heater rating
Data set 04
Published operating points and test conditions from this source.
Application
Voltage amplifier / phase inverter
Data set 05
Published operating points and test conditions from this source.
Plate Voltage
250 V
Each section
Plate Current
2.3 mA
Each section
Transconductance
1600 uS
Each section
Plate Resistance
44000 ohm
Each section
Amplification Factor
70 ratio
Each section
Data set 06
Published operating points and test conditions from this source.
Plate Voltage
250 V
ClassA1;EachUnit
Plate Current
2.3 mA
ClassA1;EachUnit
Data set 07
Published operating points and test conditions from this source.
Plate voltage
250 V
ClassA
Transconductance
1600 uS
ClassA
Plate resistance
44000 ohm
ClassA
Amplification factor
70
ClassA
Input capacitance
3 pF
Section1
Output capacitance
3 pF
Section1
Data set 08
Published operating points and test conditions from this source.
Plate Voltage
250 V
ClassA
Grid Voltage
-2 V
ClassA
Plate Current
2.3 mA
ClassA
Data set 09
Published operating points and test conditions from this source.
Voltage
6.3 V
Published datasheet value; multiple values represent separate source-table limits or conditions.
Current
300 mA
Published datasheet value; multiple values represent separate source-table limits or conditions.
Grid to plate — published value 1
2.8
Published datasheet value; multiple values represent separate source-table limits or conditions.
Grid to plate — published value 2
2.8
Published datasheet value; multiple values represent separate source-table limits or conditions.
heater — published value 1
3
Published datasheet value; multiple values represent separate source-table limits or conditions.
heater — published value 2
3.4
Published datasheet value; multiple values represent separate source-table limits or conditions.
heater — published value 1
3.8
Published datasheet value; multiple values represent separate source-table limits or conditions.
heater — published value 2
3.2
Published datasheet value; multiple values represent separate source-table limits or conditions.
Pin 1 -Grid of — published value 1
1
Published datasheet value; multiple values represent separate source-table limits or conditions.
Pin 1 -Grid of — published value 2
5
Published datasheet value; multiple values represent separate source-table limits or conditions.
Pin 2 -Plate of — published value 1
2
Published datasheet value; multiple values represent separate source-table limits or conditions.
Pin 2 -Plate of — published value 2
6
Published datasheet value; multiple values represent separate source-table limits or conditions.
Pin 3 -Cathode of — published value 1
3
Published datasheet value; multiple values represent separate source-table limits or conditions.
Pin 3 -Cathode of — published value 2
7
Published datasheet value; multiple values represent separate source-table limits or conditions.
Unit No.2
8
Published datasheet value; multiple values represent separate source-table limits or conditions.
Pin 4 -Grid of
4
Published datasheet value; multiple values represent separate source-table limits or conditions.
Plate Voltage
250 V
Published datasheet value; multiple values represent separate source-table limits or conditions.
Grid Voltage
-2 V
Published datasheet value; multiple values represent separate source-table limits or conditions.
Plate Resistance (Approx.)
44000 ohm
Published datasheet value; multiple values represent separate source-table limits or conditions.
Transconductance
1600
Published datasheet value; multiple values represent separate source-table limits or conditions.
Plate Current
2.3 mA
Published datasheet value; multiple values represent separate source-table limits or conditions.
PLATE VOLTAGE
300 V
Published datasheet value; multiple values represent separate source-table limits or conditions.
Positive bias value
0 V
Published datasheet value; multiple values represent separate source-table limits or conditions.
PLATE DISSIPATION
1 mA
Published datasheet value; multiple values represent separate source-table limits or conditions.
Heater negative with respect to cathode
90 V
Published datasheet value; multiple values represent separate source-table limits or conditions.
Heater positive with respect to cathode
90 V
Published datasheet value; multiple values represent separate source-table limits or conditions.
Data set 10
Published operating points and test conditions from this source.
Peak Heater-Cathode Voltage
90 V
TypicalOperation;PublishedValue1
Peak Heater-Cathode Voltage
90 V
TypicalOperation;PublishedValue2
Plate Voltage
300 V
MaximumRating
Grid Voltage. Positive-bias value
0 V
MaximumRating
Plate Dissipation
1 W
MaximumRating
Maximum Plate Voltage
300 V
Section1
Maximum Plate Dissipation
1 W
Section1
Grid to Plate
2.8 pF
Capacitance;PublishedValue1
Grid to Plate
2.8 pF
Capacitance;PublishedValue2
Grid to Cathode and Heater
3.4 pF
Capacitance
Plate to Cathode and Heater
3.2 pF
Capacitance
Plate Voltage
250 V
Characteristic
Grid Voltage
-2 V
Characteristic
Plate Resistance (Approx. t
44000 ohm
Characteristic
Transconductance
11500 uS
Characteristic
Plato Current
2 mA
Characteristic
Plate Resistance
44000 ohm
Section1
Amplification Factor
70
Section1