Data set 01
1975 RCA RC30
Published operating points and test conditions from this source.
Triode
Other
Heater Voltage
6.3 V
Nominal
Heater Current
200 mA
Nominal
Heater-Cathode Voltage
-450 V
Negative only; positive not recommended
Negative Grid Voltage
135 V
Peak Negative Grid Voltage
440 V
Average Plate Current
1.5 mA
Unregulated DC Supply Voltage
36000 V
ShuntVoltageRegulator
Equivalent Resistance of Unregulated Supply
11 megohm
ShuntVoltageRegulator
DC Reference Voltage
200 V
ShuntVoltageRegulator
Regulated DC Output Voltage
26000 V
LoadCurrent=0mA
Regulated DC Output Voltage
24500 V
LoadCurrent=1mA
X-Radiation Maximum Statistical Value
0.5 mR/hr
LotSampling
Capacitance
Grid-to-Plate Capacitance
1 pF
Grid-to-Cathode-and-Heater Capacitance
2.6 pF
Plate-to-Cathode-and-Heater Capacitance
1 pF
Characteristic
Effective Grid-Plate Transconductance
200 uS
ShuntVoltageRegulator