Skip to main content

Power - Beam (NOT sweep) ·BeamPower

6L6WGB

Premium ruggedized 6L6-family beam-power tube for military, industrial, and audio-output service, combining familiar amplifier characteristics with enhanced durability.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
7AC
Socket code
IO
Base pins
8
Nominal heater
6.3 V / 900 mA

Description

Premium rugged beam power tube for military, industrial, and audio-output service. Data was extracted from the supplied Tung-Sol source, including published ratings, characteristics, and operating information.

Socket description

International Octal

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
7AC
Socket code
IO
Base pins
8
Nominal heater voltage
6.3 V
Nominal heater current
900 mA
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

7AC - Terminal pinout

Electrical assignments shared by every tube using this base designation.

TerminalSectionConnectionEvidence
PIN1Pin 1—NCVerified

12L6GT/25L6GT manufacturer basing, 7AC

PIN2Pin 2—H — HeaterVerified

12L6GT/25L6GT manufacturer basing, 7AC

PIN3Pin 3AP — Plate (Anode)Verified

12L6GT/25L6GT manufacturer basing, 7AC

PIN4Pin 4AG2 — Screen GridVerified

12L6GT/25L6GT manufacturer basing, 7AC

PIN5Pin 5AG1 — Control GridVerified

12L6GT/25L6GT manufacturer basing, 7AC

PIN7Pin 7—H — HeaterVerified

12L6GT/25L6GT manufacturer basing, 7AC

PIN8Pin 8ABP — Beam-Forming PlateGroup AC8Verified

12L6GT/25L6GT manufacturer basing, 7AC

PIN8Pin 8AK — CathodeGroup AC8Verified

12L6GT/25L6GT manufacturer basing, 7AC

Section ratings

1 physical section, each with unique specifications.

Section 1

Beam Power

X-ray radiationInterelectrode capacitances
Plate resistance
22000 Ω
Transconductance
0.0052 S
Max plate voltage
360 V
Max screen voltage
270 V
Max plate dissipation
26 W
Max screen dissipation
2.5 W
Max cathode current
150 mA

Published ratings/characteristics promoted where applicable; additional source-table values retained in parameter rows.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1961 Tung Sol

Published operating points and test conditions from this source.

SECTION 1

Beam Power

Other

  • Heater voltage

    6.3 V

  • Heater current

    900 mA

  • Plate voltage

    250270360360360350 V

    Typical operating conditions

  • Plate current

    12013488887888 mA

    Typical operating conditions

Data set 02

1966 Tung Sol Electronic Tubes 3 of 4

Published operating points and test conditions from this source.

SECTION 1

Beam Power

Characteristics

  • Plate resistance

    22000 ohm

    PromotedValue

  • Transconductance

    0.0052 A/V

    PromotedValue

  • 6.3 VOLTS 0.9 AMP. — published value 1

    6.3 VOLTS

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • 6.3 VOLTS 0.9 AMP. — published value 2

    0.9 VOLTS

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • ALENT TO TYPES 61.6 ANU 6L6G, EXCEPT THAT PLATE AND SCREEN DISSIPATIONS — published value 1

    6

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • ALENT TO TYPES 61.6 ANU 6L6G, EXCEPT THAT PLATE AND SCREEN DISSIPATIONS — published value 2

    6

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • HEATER

    6.3 VOLTS

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • HEATER VOLTAGE — published value 1

    6.3 voLTs

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • HEATER VOLTAGE — published value 2

    6.3 voLTs

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • HEATER CURRENT — published value 1

    0.9 AMP

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • HEATER CURRENT — published value 2

    0.9 AMP

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • PLATE VOLTAGE — published value 1

    300 voLTs

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • PLATE VOLTAGE — published value 2

    350 voLTs

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • GRID #2 VOLTAGE — published value 1

    200 VOLTS

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • GRID #2 VOLTAGE — published value 2

    250 VOLTS

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • GRID #i VOLTAGE — published value 1

    -12.5 VOLTS

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • GRID #i VOLTAGE — published value 2

    -18 VOLTS

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • PEAK AF GRID #1 VOLTAGE — published value 1

    12.5 VOLTS

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • PEAK AF GRID #1 VOLTAGE — published value 2

    18 VOLTS

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • ZERO SIGNAL PLATE CURRENT — published value 1

    48 mA

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • ZERO SIGNAL PLATE CURRENT — published value 2

    54 mA

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • TRANSCONDUCTANCE — published value 1

    5300

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • TRANSCONDUCTANCE — published value 2

    5200

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • PLATE RESISTANCE — published value 1

    33 OHMS

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • PLATE RESISTANCE — published value 2

    0 OHMS

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • LOAD RESISTANCE — published value 1

    4500 oHMs

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • LOAD RESISTANCE — published value 2

    4200 oHMs

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

Other

  • Maximum plate voltage

    360 V

    PromotedValue

  • Maximum screen voltage

    270 V

    PromotedValue

  • Maximum plate dissipation

    26 W

    PromotedValue

  • Maximum screen dissipation

    2.5 W

    PromotedValue

  • Maximum cathode current

    150 mA

    PromotedValue

  • MAXIMUM DC PLATE

    4 VOLTS

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • MAXIMUM DC GRIC — published value 1

    3 VOLTS

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • MAXIMUM DC GRIC — published value 2

    0 VOLTS

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • MAXIMUM PLATE

    26 WATTS

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • MAXIMUM — published value 1

    2 WATTS

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • MAXIMUM — published value 2

    3 WATTS

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • MAXIMUM SIGNAL GRID #2 CURRENT' — published value 1

    4.7 mA

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • MAXIMUM SIGNAL GRID #2 CURRENT' — published value 2

    7 mA

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.

  • MAXIMUM SIGNAL PLATE CURRENT — published value 1

    55 mA

    OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.