Skip to main content

Voltage Pentode - Sharp Cutoff (single) ·Pentode

6J22P

High-frequency pentode designed for RF or wideband voltage amplification in radio-electronic equipment.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
6.3 V / 500 mA

Description

The 6J22P is a Russian high-transconductance cathode-grid pentode for wideband RF preamplification. The source entry was translated to English and processed independently from neighboring partial entries.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
6.3 V
Nominal heater current
500 mA
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Pentode

X-ray radiationInterelectrode capacitances
Plate resistance
6500 Ω
Transconductance
0.023 S
Max plate voltage
200 V
Max screen voltage
200 V
Max plate dissipation
6 W
Max screen dissipation
1.2 W

Promoted ratings and characteristics translated from the filename-designated Russian entry only.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1981 Russian Tubes Katsnelson and Larionov

Published operating points and test conditions from this source.

SECTION 1

Pentode

Characteristics

  • Guaranteed service life

    1500 h

    Published source value

  • Nominal heater voltage

    6.3 V

    Published source value

  • Nominal heater current

    500 mA

    Published source value

  • Transconductance

    23000 uS

    Published operating point

  • Plate resistance

    6500 Ohm

    Published operating point