Voltage (AC or DC) — published value 1
6.3 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Voltage (AC or DC) — published value 2
0.6 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Current at heater volts = 6.3 — published value 1
6.3 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Current at heater volts = 6.3 — published value 2
0.76 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Grid No.l to plate
0.18
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
grid No.2, and heater
13
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
grid No.2, and .heater
8
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Plate Supply Voltage — published value 1
60 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Plate Supply Voltage — published value 2
250 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Plate Supply Voltage — published value 3
250 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Grid-No.2 Supply Voltage — published value 1
250 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Grid-No.2 Supply Voltage — published value 2
125 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Grid-No.2 Supply Voltage — published value 3
250 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Grid-No.l Voltage
0 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Cathode Resistor — published value 1
33 ohm
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Cathode Resistor — published value 2
100 ohm
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Mu-Factor, Grid No.2 to Grid No.l
33
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Plate Resistance (Approx ) — published value 1
28000 ohm
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Plate Resistance (Approx ) — published value 2
24000 ohm
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Transconductance — published value 1
24000
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Transconductance — published value 2
20000
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Plate Current — published value 1
150 mA
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Plate Current — published value 2
40 mA
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Plate Current — published value 3
40 mA
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Grid-No.2 Current — published value 1
37 mA
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Grid-No.2 Current — published value 2
4.2 mA
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Grid-No.2 Current — published value 3
6.2 mA
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
for plate µa = 100 — published value 1
100 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
for plate µa = 100 — published value 2
-6.4 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
for plate µa = 100 — published value 3
-13 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Pin 1 -Cathode — published value 1
1
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Pin 1 -Cathode — published value 2
6
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Pin 2 -Grid No.l — published value 1
2
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Pin 2 -Grid No.l — published value 2
7
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Pin 3 -Grid No.3 — published value 1
3
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Pin 3 -Grid No.3 — published value 2
8
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Pin 4 -Heater — published value 1
4
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Pin 4 -Heater — published value 2
9
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Pin 5 -Heater
5
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.