Skip to main content

Voltage - Triple Triode ·Triode-Triode-Triode

6GY8

High-mu triple triode for multi-stage voltage-amplifier and signal-processing circuits.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
3
Base
-
Socket code
B9A
Base pins
9
Nominal heater
6.3 V / 450 mA

Description

Miniature high-mu triple triode intended for RF amplifier, autodyne mixer, and automatic-frequency-control service in FM receivers.

Socket description

Small-button Noval 9-contact

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
B9A
Base pins
9
Nominal heater voltage
6.3 V
Nominal heater current
450 mA
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

3 physical sections, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Plate resistance
14000 Ω
Transconductance
0.0045 S
Amplification factor
63
Max plate voltage
330 V
Max plate dissipation
2 W
Rectifier max heater-cathode voltage
100 V

Each identical section; total all-plate dissipation 5 W.

Section 2

Triode

X-ray radiationInterelectrode capacitances
Plate resistance
14000 Ω
Transconductance
0.0045 S
Amplification factor
63
Max plate voltage
330 V
Max plate dissipation
2 W

Second identical physical triode section; added to align rows with SectionCount.

Section 3

Triode

X-ray radiationInterelectrode capacitances
Plate resistance
14000 Ω
Transconductance
0.0045 S
Amplification factor
63
Max plate voltage
330 V
Max plate dissipation
2 W

Third identical physical triode section; added to align rows with SectionCount.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1968 General Electric Co

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Total Plate Dissipation All Plates

    5 W

    AllSections