Data set 01
1961 Tung Sol
Published operating points and test conditions from this source.
Pentode
Other
Heater voltage
6.3 V
Heater current
450 mA
Plate voltage
300 V
Typical operating conditions
Plate current
3.7 mA
Typical operating conditions
Voltage Pentode - Sharp Cutoff (single) ·Pentode
Dual-control sharp-cutoff pentode for television FM detection, gated AGC, and noise-inverter signal-processing circuits.
Sharp-cutoff dual-control-grid pentode for gated AGC and television noise-inverter service.
Miniature 7-contact
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
| Terminal | Section | Connection | Evidence |
|---|---|---|---|
| PIN1G1 | A | G1 — Control Grid Chart transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 129, 7EN |
| PIN2IS | A | IS — Internal ScreenGroup 7EN2 Chart transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 129, 7EN |
| PIN2K | A | K — CathodeGroup 7EN2 Chart transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 129, 7EN |
| PIN3H | — | H — Heater Chart transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 129, 7EN |
| PIN4H | — | H — Heater Chart transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 129, 7EN |
| PIN5P | A | P — Plate (Anode) Chart transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 129, 7EN |
| PIN6G2 | A | G2 — Screen Grid Chart transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 129, 7EN |
| PIN7G3 | A | G3 — Suppressor Grid Chart transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 129, 7EN |
1 physical section, each with unique specifications.
Section 1
Dual-control pentode; grid-3-to-plate transconductance preserved as parameter.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Heater voltage
6.3 V
Heater current
450 mA
Plate voltage
300 V
Typical operating conditions
Plate current
3.7 mA
Typical operating conditions
Data set 02
Published operating points and test conditions from this source.
Grid 1 to plate capacitance
0.026 pF
Grid 1 input capacitance
8 pF
Grid 1 to grid 3 capacitance
0.12 pF
Grid 3 to plate capacitance
1.6 pF
Grid 3 total capacitance
6.5 pF
Plate supply voltage
150 V
ClassA1
Grid 2 supply voltage
100 V
ClassA1
Cathode resistor
180 ohm
ClassA1
Plate current
3.7 mA
ClassA1
Grid 2 current
3 mA
ClassA1
Grid 3 transconductance
750 µS
ClassA1
Data set 03
Published operating points and test conditions from this source.
Grid3 Transconductance
750 uS
Typical Plate Current
3.7 mA
Typical Screen Current
3 mA
TypicalPlateSupplyVoltage
150 V
TypicalScreenSupplyVoltage
100 V
Data set 04
Published operating points and test conditions from this source.
Plate voltage
150 V
ClassA
Plate current
3.7 mA
ClassA
Maximum plate voltage
330 V
Maximum screen-grid voltage
330 V
PLATE VOLTAGE
300 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
GRID-No.2 (SCREEN-GRID) SUPPLY VOLTAGE
300 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Negative-bias value
50 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Positive-bias value
0 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
For grid-No.2 voltages up to 150 volts — published value 1
150 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
For grid-No.2 voltages up to 150 volts — published value 2
1 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
GRID-No.3 INPUT
0.1 mA
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
PLATE DISSIPATION
1.7 mA
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Heater negative with respect to cathode
200 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Heater positive with respect to cathode
2006 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Grid-No.3-Circuit Resistance — published value 1
0 mA
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Grid-No.3-Circuit Resistance — published value 2
68 mA
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
For fixed-bias operation
0.22 mA
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
For cathode-bias operation — published value 1
0 mA
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
For cathode-bias operation — published value 2
47 mA
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Plate resistance
140000 ohm
ClassA
Transconductance
3700 uS
ClassA
Voltage (AC or DC)
6.3 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Current — published value 1
450 mA
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Current — published value 2
6 A
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Warm-up time (Average)
11
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Grid No.1 to plate
0.022
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
and heater
8
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Grid No.3 to plate
1.6
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Grid No.l to grid No 3 — published value 1
3
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Grid No.l to grid No 3 — published value 2
0.11
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
No.1, and heater
7.5
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Plate Supply Voltage
150 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Grid-No.3 Supply Voltage
0 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Grid-No.2 Supply Voltage
100 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Grid-No.l Supply Voltage
0 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Cathode Resistor
180 ohm
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Plate Resistance (Approx )
0.14 Mohm
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Transconductance, Grid No.l to Plate
3700
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Transconductance, Grid No.3 to Plate
750
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Plate Current
3.7 mA
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Grid-No.2 Current
3 mA
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
for plate µa = 20 — published value 1
20 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
for plate µa = 20 — published value 2
-4.5 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
for plate µa = 20 — published value 1
20 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
for plate µa = 20 — published value 2
-7 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Pin 1 -Grid No.l — published value 1
1
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Pin 1 -Grid No.l — published value 2
4
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Pin 2 -Cathode, — published value 1
2
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Pin 2 -Cathode, — published value 2
5
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Internal
6
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Shield
7
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Pin 3 -Heater
3
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
For grid-No.2 voltages between 150
150 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
and 300 volts
300 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
GRID-No.2 VOLTS=100
100 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
PLATE (Iy)OR GRID-No.2 (I~2) MILLIAMPERES
2 mA
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
PLATE VOLTS=150
150 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
GRID—No.2 VOLTS=100
100 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
GRID—Na2 VOLTS=100
100 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
GRID—No.2 VOLTS = 100
100 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Data set 05
Published operating points and test conditions from this source.
Grid No.1-to-plate capacitance
0.026 pF
Grid No.1-to-Grid No.3 capacitance
0.12 pF
Grid No.3-to-plate capacitance
1.6 pF
Plate supply voltage
150 V
ClassA
Screen-grid supply voltage
100 V
ClassA
Cathode-bias resistor
180 ohm
ClassA
Plate current
3.7 mA
ClassA
Peak positive-pulse plate voltage
600 V
GatedAGC
Transconductance Grid No.3 to plate
750 uS