Plate resistance
15000 ohm
ClassA
Transconductance
7100 uS
ClassA
Voltage (AC or DC) — published value 1
6 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Voltage (AC or DC) — published value 2
3 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Voltage (AC or DC) — published value 3
10 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Current at 6.3 volts — published value 1
6.3 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Current at 6.3 volts — published value 2
1 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Current at 6.3 volts — published value 3
2 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
for plate volts = 150, grid-No.2
150 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
volts = 150, grid-No.l volts =
150 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Grid No.l to plate
5
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
grid Na.2, and heater
17
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
grid No.2, and heater
7
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Plate Voltage — published value 1
60 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Plate Voltage — published value 2
250 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Grid-No.2 Voltage — published value 1
150 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Grid-No.2 Voltage — published value 2
150 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Grid-No.l Voltage — published value 1
0 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Grid-No.l Voltage — published value 2
-22.5 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Plate Resistance (Approx 1 — published value 1
1 ohm
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Plate Resistance (Approx 1 — published value 2
15000 ohm
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Transconductance
7100
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Plate Current — published value 1
3906 mA
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Plate Current — published value 2
70 mA
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Grid-No.2 Current — published value 1
326 mA
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Grid-No.2 Current — published value 2
2.1 mA
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
plate ma. = 1 — published value 1
1 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
plate ma. = 1 — published value 2
-42 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Pin 2 -Heater — published value 1
2
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Pin 2 -Heater — published value 2
7
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Pin 3 -No Connec — published value 1
3
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Pin 3 -No Connec — published value 2
8
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Pin 4 -Grid No.2
4
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Pin 5 -Grid No.i
5
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
GRID-N42 VOLTS=150
150 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
GRID-N°2 MILLIAMPERES ~IC2~
2 mA
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.