Voltage (AC or DC) — published value 1
6.3 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Voltage (AC or DC) — published value 2
0.6 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Current at heater volts = 6 3 — published value 1
6 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Current at heater volts = 6 3 — published value 2
3 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Current at heater volts = 6 3 — published value 3
1.2 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Pin 1 -Heater
1
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Pin 3 -Grid No.2
3
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Pin 4 -Cathode, Grid No.3
4
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Pin 5 -Grid No.1
5
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Pin 7 -Grid No.2
7
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Pin 9 -Grid No.1
9
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Pin 11-Grid No.2
11
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Pin 12 -Heater
12
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Plate Voltage — published value 1
5000 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Plate Voltage — published value 2
60 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Plate Voltage — published value 3
250 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Plate Voltage — published value 4
150 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Grid-No.2 Voltage — published value 1
150 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Grid-No.2 Voltage — published value 2
150 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Grid-No.2 Voltage — published value 3
150 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Grid-No.2 Voltage — published value 4
150 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Grid-No.l Voltage — published value 1
0 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Grid-No.l Voltage — published value 2
-22.5 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Grid-No.l Voltage — published value 3
-22.5 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Plate Resistance (Approx.)
18000 ohm
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Transconductance
7300
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Plate Current — published value 1
345 mA
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Plate Current — published value 2
65 mA
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Grid-No.2 Current — published value 1
27 mA
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
Grid-No.2 Current — published value 2
1.8 mA
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
plate ma.= 1 — published value 1
1 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
plate ma.= 1 — published value 2
100 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
plate ma.= 1 — published value 3
42 V
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.
9 An adequate bias resistor or other means is requiretl to protect the tube
9
Published datasheet value; multiple values on one source row represent separate limits or operating conditions.