Skip to main content

Tube cross-reference

6G5 alternatives, equivalents, and replacements

Review exact electrical variations and directional substitutions recorded for the 6G5 tuning indicator. Compare core specifications and verify every restriction before using a replacement.

Exact variations of 6G5

These designations belong to the same electrical variation group. Their names may differ because of international standards, manufacturing tolerances, or materials, but they are recorded as electrically equivalent—not merely substitutes.

  • 6U5

    Tuning Indicator

    Base
    6R
    Socket
    UX6
    Base pins
    6
    Sections
    2
    Heater voltage
    6.3 V
    Heater current
    0.3 A

Replacement tubes for 6G5

The following tubes are recorded as possible replacements for 6G5. This direction does not establish that 6G5 can replace them.

6H5

Tuning Indicator

Receiving Tubes

The database records 6H5 as a possible replacement for6G5.

No special restrictions are recorded for this substitution.

SpecificationOriginal tubeReplacement
Tube typeTuning IndicatorTuning Indicator
ConstructionTriode-TuningIndicatorTriode-TuningIndicator
BaseNot recordedNot recorded
SocketUX6IO
Base pins6Not recorded
Sections22
Heater voltage6.3 V6.3 V
Heater current0.3 A0.3 A
6T5

Tuning Indicator

Receiving Tubes

The database records 6T5 as a possible replacement for6G5.

No special restrictions are recorded for this substitution.

SpecificationOriginal tubeReplacement
Tube typeTuning IndicatorTuning Indicator
ConstructionTriode-TuningIndicatorTriode-TuningIndicator
BaseNot recorded6R
SocketUX6UX6
Base pins66
Sections22
Heater voltage6.3 V6.3 V
Heater current0.3 A0.3 A
6U5

Tuning Indicator

Receiving Tubes

The database records 6U5 as a possible replacement for6G5.

No special restrictions are recorded for this substitution.

SpecificationOriginal tubeReplacement
Tube typeTuning IndicatorTuning Indicator
ConstructionTriode-TuningIndicatorTriode-TuningIndicator
BaseNot recorded6R
SocketUX6UX6
Base pins66
Sections22
Heater voltage6.3 V6.3 V
Heater current0.3 A0.3 A

Where 6G5 can be used as the replacement

In these recorded relationships, 6G5 is the replacement tube. The listed original tubes are not automatically suitable as replacements for 6G5.

6E5

Tuning Indicator

Receiving Tubes

The database records 6G5 as a possible replacement for6E5.

  • Not suitable for all circuits
Specification6G5 replacementOriginal tube
Tube typeTuning IndicatorTuning Indicator
ConstructionTriode-TuningIndicatorTriode-TuningIndicator
BaseNot recorded6R
SocketUX6UX6
Base pins66
Sections22
Heater voltage6.3 V6.3 V
Heater current0.3 A0.3 A
6H5

Tuning Indicator

Receiving Tubes

The database records 6G5 as a possible replacement for6H5.

No special restrictions are recorded for this substitution.

Specification6G5 replacementOriginal tube
Tube typeTuning IndicatorTuning Indicator
ConstructionTriode-TuningIndicatorTriode-TuningIndicator
BaseNot recordedNot recorded
SocketUX6IO
Base pins6Not recorded
Sections22
Heater voltage6.3 V6.3 V
Heater current0.3 A0.3 A
6T5

Tuning Indicator

Receiving Tubes

The database records 6G5 as a possible replacement for6T5.

No special restrictions are recorded for this substitution.

Specification6G5 replacementOriginal tube
Tube typeTuning IndicatorTuning Indicator
ConstructionTriode-TuningIndicatorTriode-TuningIndicator
BaseNot recorded6R
SocketUX6UX6
Base pins66
Sections22
Heater voltage6.3 V6.3 V
Heater current0.3 A0.3 A
6U5

Tuning Indicator

Receiving Tubes

The database records 6G5 as a possible replacement for6U5.

No special restrictions are recorded for this substitution.

Specification6G5 replacementOriginal tube
Tube typeTuning IndicatorTuning Indicator
ConstructionTriode-TuningIndicatorTriode-TuningIndicator
BaseNot recorded6R
SocketUX6UX6
Base pins66
Sections22
Heater voltage6.3 V6.3 V
Heater current0.3 A0.3 A

Verify before substituting

Matching a base or heater voltage is not enough to prove that two tubes are interchangeable. Check pin connections, heater current, maximum ratings, bias requirements, warm-up behavior, and the equipment manufacturer’s service documentation before making a substitution.