Data set 01
1959 Ediswan
Published operating points and test conditions from this source.
Pentode
Application
Application
HF amplifier
Voltage Pentode - High Frequency (single) ·Pentode
Screened high-frequency pentode developed for television and other wideband amplifier service.
Screened HF pentode for television or high-frequency amplifier service.
Small-button Noval 9-contact
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Ediswan/Mazda 6EL7 nine-pin B9A high-frequency screened pentode for television and broadband amplification. Manufacturer heater 6.3 V 0.3 A, maximum anode 250 V and screen 250 V; nominal transconductance 9.2 mA/V (0.0092 S), measured under specified bias conditions. Original manufacturer sheet includes 3 W anode and 1 W screen general ratings but condition-dependent limits of 2 W anode and 0.5 W screen; these existing more restrictive promoted dissipation values retained pending operating-condition reconciliation. Typical Va/Vg2 near 170 V with 10 mA anode and 2.6 mA screen current. Shielded and holder-dependent electrode capacitances published; existing capacitance flag true preserved. Do not confuse conditional power ratings with unrestricted absolute maxima.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Application
HF amplifier