Data set 01
1938 Raytheon
Published operating points and test conditions from this source.
Beam Power
Other
Heater voltage 6.3 9.4
12.6 V
Heater voltage 6.3 9.4 12,6 volts
Heater current 0.9 0.8
450 mA
Heater current 0.9 0.8 0,45 amps
Total DC and peak
200 V
Total DC and peak 200 volts
Total DC and peak
200 V
Total DC and peak 200 volts
Maximum plate voltage
250 V
Maximum plate voltage 250 volts
Maximum grid #2 voltage
250 V
Maximum grid #2 voltage 250 volts
** Maximum peak positive pulse plate voltage (abs., max.)
2000 V
** Maximum peak positive pulse plate voltage (abs., max.) 2000 volts
Maximum plate dissipation
10 W
Maximum plate dissipation 10 watts
Maximum peak negative pulse grid #1 voltage
250 V
Maximum peak negative pulse grid #1 voltage 250 volts
Maximum grid #2 dissipation
2 W
Maximum grid #2 dissipation 2.0 watts
Maximum average cathode current
60 mA
Maximum average cathode current 60 ma,
Maximum peak cathode current
180 mA
Maximum peak cathode current 180 ma.
* Maximum grid #1 circuit resistance (Rk=100 ohm minimum)
2.2 MΩ
* Maximum grid #1 circuit resistance (Rk=100 ohm minimum) 2,2 megohms
Heater voltage 6.3 0.4
12.6 V
Heater voltage 6.3 0.4 12.6 volts
Plate voltage
250 V
Plate voltage 250 volts
Grid #2 voltage
250 V
Grid #2 voltage 250 volts
Plate current
50 mA
Plate current 50 ma,
Grid #2 current
2 mA
Grid #2 current 2 ma,
Transconductance
5000 µS
Transconductance 5000 umhos
Grid #1 voltage (approx.) for Ib = 1 milliampere
-40 V
Grid #1 voltage (approx.) for Ib = 1 milliampere -40 volts