Data set 01
1959 Rogers
Published operating points and test conditions from this source.
Tuning Indicator
Application
Application
Visual tuning indication
Triode
Application
Application
Indicator control amplifier
Tuning Indicator ·Triode-TuningIndicator
Electron-ray visual indicator for receiver tuning or electrical level indication, using a fluorescent display whose pattern changes with control voltage.
Double-sensitivity electron-ray tuning indicator that gives clear indication even with weak signals.
International Octal
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
2 physical sections, each with unique specifications.
Section 1
Electron-ray display section.
Section 2
No fixed ratings are recorded for this section.
Published Rogers/JETEC/RMA ratings and characteristics promoted where applicable; additional data retained as parameters.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Application
Visual tuning indication
Application
Indicator control amplifier
Data set 02
Published operating points and test conditions from this source.
Maximum target voltage
300 V
TuningIndicator
Plate voltage
250 V
TuningIndicator
Plate resistor per plate
1000000 ohm
TuningIndicator
Target voltage
250 V
TuningIndicator
Grid voltage for sector 2 minimum shadow
-16 V
TuningIndicator
Grid voltage for sector 1 minimum shadow
-5 V
TuningIndicator
Grid voltage for 180 degree shadow
0 V
TuningIndicator
Data set 03
Published operating points and test conditions from this source.
Plate and target supply voltage
250 V
TuningIndicator
Target current
2 mA
TuningIndicator
Application
Double-sensitivity tuning indicator
Section1
Grid bias end of control range section 1
-5 V
TuningIndicator;Section1
Grid bias end of control range section 2
-16 V
TuningIndicator;Section2