Data set 01
1958 Mullard Receiving Tubes
Published operating points and test conditions from this source.
Pentode
Application
Application
RF / IF amplifier
Voltage Pentode ·Pentode
High-transconductance sharp-cutoff pentode developed for television RF and IF amplification in VHF tuner and intermediate-frequency stages.
Indirectly heated fixed-slope pentode intended for RF amplification.
Miniature 7-contact
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
| Terminal | Section | Connection | Evidence |
|---|---|---|---|
| PIN1G1 | A | G1 — Control Grid EIA chart transcription; manufacturer verification pending | Unverified EIA Base Connections, printed page 128, 7CM |
| PIN2K | A | K — Cathode EIA chart transcription; manufacturer verification pending | Unverified EIA Base Connections, printed page 128, 7CM |
| PIN3H | — | H — Heater EIA chart transcription; manufacturer verification pending | Unverified EIA Base Connections, printed page 128, 7CM |
| PIN4H | — | H — Heater EIA chart transcription; manufacturer verification pending | Unverified EIA Base Connections, printed page 128, 7CM |
| PIN5P | A | P — Plate (Anode) EIA chart transcription; manufacturer verification pending | Unverified EIA Base Connections, printed page 128, 7CM |
| PIN6G2 | A | G2 — Screen Grid EIA chart transcription; manufacturer verification pending | Unverified EIA Base Connections, printed page 128, 7CM |
| PIN7G3 | A | G3 — Suppressor GridGroup 7CM7 EIA chart transcription; manufacturer verification pending | Unverified EIA Base Connections, printed page 128, 7CM |
| PIN7IS | A | IS — Internal ScreenGroup 7CM7 EIA chart transcription; manufacturer verification pending | Unverified EIA Base Connections, printed page 128, 7CM |
1 physical section, each with unique specifications.
Section 1
Sharp-cutoff pentode.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Application
RF / IF amplifier
Data set 02
Published operating points and test conditions from this source.
Plate voltage
200 V
ClassA
Screen-grid voltage
150 V
ClassA
Cathode resistor
180 ohm
ClassA
Plate current
9.5 mA
ClassA
Screen-grid current
2.8 mA
ClassA
Input capacitance
6.5 pF
Output capacitance
2 pF
Grid-to-plate capacitance
0.02 pF
Data set 03
Published operating points and test conditions from this source.
Heater voltage
6.3 V
Heater current
300 mA
Plate voltage
330 V
Typical operating conditions
Plate current
13 mA
Typical operating conditions
Data set 04
Published operating points and test conditions from this source.
Input capacitance
6.5 pF
Shielded
Output capacitance
3 pF
Shielded
Grid-to-plate capacitance maximum
0.01 pF
Shielded
Plate voltage
200 V
Screen-grid voltage
150 V
Control-grid voltage
-2.2 V
Plate current
9.5 mA
Screen-grid current
2.8 mA
Plate resistance
600000 Ohm
Transconductance
8000 uS
Control-grid cutoff voltage
-8 V
Ia=10uA
Plate cold voltage
550 V
Screen-grid cold voltage
550 V
Heater-to-cathode voltage peak
200 V
Data set 05
Published operating points and test conditions from this source.
Plate voltage
125 V
Screen-grid voltage
125 V
Cathode bias resistor
56 Ohm
Plate current
13 mA
Plate resistance
280000 Ohm
Transconductance
8000 uS
Control-grid cutoff voltage
-6.5 V
Grid-to-plate capacitance
0.025 pF
Unshielded
Input capacitance
6.5 pF
Unshielded
Output capacitance
2 pF
Unshielded
Data set 06
Published operating points and test conditions from this source.
Heater Voltage
6.3 V
Heater Current
300 mA
Transconductance
10000 uS
RepresentativePublishedPoint
Plate Resistance
280000 ohm
RepresentativePublishedPoint
Maximum Plate Voltage
330 V
Maximum Plate Dissipation
2.3 W
Data set 07
Published operating points and test conditions from this source.
Grid-to-plate capacitance without shield
0.025 pF
Grid-to-plate capacitance with shield
0.015 pF
Input capacitance
6.5 pF
Output capacitance without shield
2 pF
Output capacitance with shield
3 pF
Plate voltage
125 V
ClassA
Grid #2 voltage
125 V
ClassA
Cathode bias resistor
56 ohm
ClassA
Plate current
13 mA
ClassA
Grid #2 current
3.7 mA
ClassA
Grid #1 voltage at 20 uA plate current
-6.5 V
Data set 08
Published operating points and test conditions from this source.
Heater voltage ….….……...….….…cesenserse caonde conmessnee vf
6.33 V
Heater current … … If
300 MA
Tension d'anod@E ...c Va
300 V
Screen-grid voltage …..………..…ececririnerecenesennennnnennns V8a
150 V
Plate dissipation …… ; … Pa
2 W
Screen-grid dissipation … . … Peg,
0.5 W
TTension de crête entre f11ament et cathode mueeer VEKCT
200 V
Tension d'AnOdE ….......…..….…erereesrieeneenansesinncnes Vä
200 V
Screen-grid voltage ...c VEZ
150 V
RÉSISTANCE INtEInE ….…riresenaiereennsennnnennnnnnnnnne P
6 MΩ
Transconductance
6.2 mA/V
ce VEL bl
-8 V
cccc T
9.5 mA
Courant de grille n° 2 ….….......…eerensesecerereenceceness Î2
2.8 mA
ï Va =
0 V
Capacitance d'entrée
6.3 pF
InterelectrodeCapacitance
Capacitance de sortie
1.9 pF
InterelectrodeCapacitance
Capacitance anode/ grille n° 1 ….c Ca/ @
20 pF
InterelectrodeCapacitance
Capacitance d'entrée ….…….……ererermescerenenamatenne Ce
6.5 pF
InterelectrodeCapacitance
Capacitance de sortie ……n Cs
3 pF
InterelectrodeCapacitance
Capacitance anode/ grille n° 1 ……c Ca/ ë;
10 pF
InterelectrodeCapacitance
Data set 09
Published operating points and test conditions from this source.
Heater negative with respect to cathode
200 V
Heater positive with respect to cathode
2004 V
E ~. =
6.3 V
GRtD-N
42 V
Published table column 1 of 2
GRtD-N
150 V
Published table column 2 of 2
Ep=
8.3 V
PLATE VOLTS=
200 V
GRID-Ns
2 V
Published table column 1 of 2
GRID-Ns
50 V
Published table column 2 of 2
Plate Voltage
200 V
Cathode—Bias Resistor
180 Ω
Plate Resistance (Approx )
0.6 MΩ
Transconductance
6200 µS
plate current of
10 V
Plate Current
9.5 mA
Grid—No
2 mA
Published table column 1 of 2
Grid—No
2.8 mA
Published table column 2 of 2