Skip to main content

Power - Triode (over 1000V 100W) ·Triode

6C23

Forced-air-cooled UHF pulse-oscillator power triode.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
7 V / 26 A

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
7 V
Nominal heater current
26 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 0

Triode

X-ray radiationInterelectrode capacitances
Amplification factor
12
Max plate dissipation
1000 W

UHF pulse oscillator triode, forced-air cooled; maximum service frequency 600 MHz.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

9999 Mixed G 1000

Published operating points and test conditions from this source.

SECTION 0

Triode

Other

  • Heater/filament voltage

    7 V

    Approximate heater voltage

  • Heater/filament current

    26 A

    Approximate heater current

  • Maximum plate voltage

    15000 V

    Maximum DC plate voltage, pulse oscillator service