Data set 01
195X General Electric Essential Characteristics
Published operating points and test conditions from this source.
Triode
Other
Plate voltage
250 V
Section1 VerticalDeflection
Control-grid voltage
-15 V
Section1 VerticalDeflection
Positive pulse plate voltage maximum
1500 V
Section1 VerticalDeflection
Plate dissipation maximum
7.5 W
Section1 VerticalDeflection
Triode
Other
Plate voltage
120 V
Section2 ClassA
Control-grid voltage
-10 V
Section2 ClassA
Plate current
5 mA
Section2 ClassA
Characteristic
Plate resistance
14000 Ω
Section2 ClassA
Transconductance
2000 µS
Section2 ClassA
Amplification factor
28
Section2 ClassA