Data set 01
1965 Ericsson Longlife
Published operating points and test conditions from this source.
Pentode
Other
Plate supply voltage
130 V
ClassA
Screen-grid supply voltage
130 V
ClassA
Cathode bias resistor
200 Ohm
ClassA
Plate current
23 mA
ClassA
Screen-grid current
2 mA
ClassA
Load resistance
6000 Ohm
ClassA
Power output
1 W
ClassA
Total harmonic distortion
7 %
ClassA
Plate supply voltage
180 V
ClassA
Screen-grid supply voltage
180 V
ClassA
Plate current
32.5 mA
ClassA
Load resistance
8000 Ohm
ClassA;Va=180V
Power output
2.1 W
ClassA;Va=180V
Transconductance minimum
2600 uS
Transconductance maximum
4200 uS
Characteristics
Transconductance
3400 uS
ClassA
Plate resistance
0.08 MOhm
ClassA
Transconductance
3900 uS
ClassA;Va=180V