Data set 01
1958 Compagnie General
Published operating points and test conditions from this source.
Pentode
Characteristic
Operating Frequency Maximum
400 MHz
Plate Resistance
500000 ohm
Transconductance
5100 uS
Other
Plate Dissipation
1.65 W
Voltage Pentode - Sharp Cutoff (single) ·Pentode
Ruggedized special-quality sharp-cutoff pentode for wideband radar, RF, and IF amplification in military and airborne equipment.
Ruggedized sharp-cutoff miniature pentode characterized by low heater power, high transconductance and low capacitances for high-frequency wide-band radar and IF service in military and industrial airborne equipment.
Miniature 7-contact
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
| Terminal | Section | Connection | Evidence |
|---|---|---|---|
| PIN1G1 | A | G1 — Control Grid EIA transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 128, 7BD |
| PIN2G3 | A | G3 — Suppressor GridGroup 7BD2 EIA transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 128, 7BD |
| PIN2IS | A | IS — Internal ScreenGroup 7BD2 EIA transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 128, 7BD |
| PIN2K | A | K — CathodeGroup 7BD2 EIA transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 128, 7BD |
| PIN3H | — | H — Heater EIA transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 128, 7BD |
| PIN4H | — | H — Heater EIA transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 128, 7BD |
| PIN5P | A | P — Plate (Anode) EIA chart transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 128, 7BD |
| PIN6G2 | A | G2 — Screen Grid EIA chart transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 128, 7BD |
| PIN7G3 | A | G3 — Suppressor GridGroup 7BD7 EIA chart transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 128, 7BD |
| PIN7IS | A | IS — Internal ScreenGroup 7BD7 EIA chart transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 128, 7BD |
| PIN7K | A | K — CathodeGroup 7BD7 EIA chart transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 128, 7BD |
1 physical section, each with unique specifications.
Section 1
Promoted only from clearly identified printed ratings/characteristics; additional published operating points retained in TUBE_SECTION_PARAMETER.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Operating Frequency Maximum
400 MHz
Plate Resistance
500000 ohm
Transconductance
5100 uS
Plate Dissipation
1.65 W
Data set 02
Published operating points and test conditions from this source.
Control-grid voltage
-2 V
RFAmplifier
Plate voltage
120 V
RFAmplifier
Screen voltage
120 V
RFAmplifier
Plate current
7.5 mA
RFAmplifier
Screen current
2.5 mA
RFAmplifier
Plate resistance
340000 Ω
Section1
Transconductance
5000 µS
Section1
Data set 03
Published operating points and test conditions from this source.
Plate resistance
340000 ohm
PromotedValue
Transconductance
0.0051 A/V
PromotedValue
HEATER VOLTAGE — published value 1
6 VOLTS
OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.
HEATER VOLTAGE — published value 2
1 VOLTS
OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.
NEATER VOLTAGE
6 VOLTS
OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.
NEATER CURRENT
0.175 AMP
OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.
PLATE VOLTAGE
120 VOLT
OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.
GRID 1F2 VOLTAGE — published value 1
2 VOLTS
OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.
GRID 1F2 VOLTAGE — published value 2
120 VOLTS
OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.
CATHODE BIAS RESISTOR B
200 OHMS
OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.
PLATE RESISTANCE (APPROX.)
4 MEGOHM
OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.
TRANSCONDUC TA HCE
5000
OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.
PLATE CURRENT
7.5 mA
OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.
GR I~D ~E2 CURRENT — published value 1
2 mA
OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.
GR I~D ~E2 CURRENT — published value 2
2.5 mA
OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.
GRID Ni VOLTAGE (APPR Ox,) Ip=10 µa — published value 1
10
OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.
GRID Ni VOLTAGE (APPR Ox,) Ip=10 µa — published value 2
-12
OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.
HEATER CURRENT — published value 1
160 mA
OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.
HEATER CURRENT — published value 2
190 mA
OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.
PLATE CURRENT (1) — published value 1
4.5 mAdC
OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.
PLATE CURRENT (1) — published value 2
11 mAdC
OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.
TRANSCONOUC TA NCE (i) — published value 1
3751 µMHOS
OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.
TRANSCONOUC TA NCE (i) — published value 2
6250 µMHOS
OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.
SCREEN CURRENT — published value 1
1.3 mAdc
OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.
SCREEN CURRENT — published value 2
3.2 mAdc
OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.
PLATE CURRENT (3)
3
OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.
TRANSCONDUCTANCE (2)D
2
OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.
GRID CURRENT (2)E
2
OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.
Maximum plate voltage
200 V
PromotedValue
Maximum screen voltage
155 V
PromotedValue
Maximum plate dissipation
1.65 W
PromotedValue
Maximum screen dissipation
0.55 W
PromotedValue
Maximum cathode current
20 mA
PromotedValue
MAXIMUM DC PLATE VOLTAGE
2
OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.
MAXIMUM OC GRID M2 VOLTAGE — published value 1
2 VOLTS
OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.
MAXIMUM OC GRID M2 VOLTAGE — published value 2
155 VOLTS
OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.
MAXIMUM PLATE DISSIPATION
1.65 WATTS
OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.
MAXIMUM HEATER CATHODE VOLTAGE
130 VOLTS
OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.
MAXIMUM GRID ,Y2 DISSIPATION — published value 1
2 WATT
OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.
MAXIMUM GRID ,Y2 DISSIPATION — published value 2
0.55 WATT
OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.
MAXIMUM BULB TEMPERATURE
165
OCR table transcription; verify against supplied datasheet layout where multiple columns represent operating conditions.