Data set 01
1950 Sylvania
Published operating points and test conditions from this source.
Triode
Other
Typical plate supply voltage
165 V
Voltage - Triode (single) ·Triode
General-purpose triode for receiving, amplification, driver, or electronic service as documented by the manufacturer.
Voltage-amplifier triode used principally as a driver tube.
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Published promoted fields populated from the datasheet; identical repeated sections compressed where applicable.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Typical plate supply voltage
165 V
Data set 02
Published operating points and test conditions from this source.
Plate voltage
180 V
ClassA
Grid voltage
-18 V
ClassA
Plate current
7 mA
ClassA
Data set 03
Published operating points and test conditions from this source.
Power Output
3.3 W
Approx10PercentTotalDistortion
Plate Voltage
180 V
Typical