Skip to main content

Tuning Indicator ·Triode-TuningIndicator

6AB5

Electron-ray visual indicator for receiver tuning or electrical level indication, using a fluorescent display whose pattern changes with control voltage.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
2
Base
6R
Socket code
-
Base pins
6
Nominal heater
6.3 V / 150 mA

Description

Triode indicator tube using a fluorescent target to provide a visible indication for tuning or similar level-display service.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
6R
Socket code
-
Base pins
6
Nominal heater voltage
6.3 V
Nominal heater current
150 mA
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

6R - Terminal pinout

Electrical assignments shared by every tube using this base designation.

TerminalSectionConnectionEvidence
PIN1H—H — Heater

EIA chart transcription; independent manufacturer verification pending

Unverified

EIA Base Connections, printed page 127, 6R

PIN2DAOTHER — Other Identified Element

Source D denotes deflecting electrode; generic OTHER element 40 pending canonical refinement

Unverified

EIA Base Connections, printed page 127, 6R

PIN3G1AG1 — Control Grid

EIA chart transcription; independent manufacturer verification pending

Unverified

EIA Base Connections, printed page 127, 6R

PIN4TAT — Target

EIA chart transcription; independent manufacturer verification pending

Unverified

EIA Base Connections, printed page 127, 6R

PIN5KAK — Cathode

EIA chart transcription; independent manufacturer verification pending

Unverified

EIA Base Connections, printed page 127, 6R

PIN7H—H — Heater

EIA chart transcription; independent manufacturer verification pending

Unverified

EIA Base Connections, printed page 127, 6R

Section ratings

2 physical sections, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Max plate voltage
135 V

Published promoted fields populated from the datasheet; identical repeated sections compressed where applicable.

Section 2

Tuning Indicator

X-ray radiationInterelectrode capacitances

No fixed ratings are recorded for this section.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1937 Raytheon Radio Receiving Tubes

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Target voltage maximum

    135 V

    TuningIndicator

  • Plate supply voltage

    135 V

    TuningIndicator

  • Target voltage

    135 V

    TuningIndicator

  • Plate resistor

    0.25 MΩ

    TuningIndicator

  • Target current

    4.5 mA

    TuningIndicator

  • Plate current

    0.5 mA

    ZeroBias

  • Grid bias

    -7.5 V

    Shadow0Degrees

  • Grid bias

    0 V

    Shadow90Degrees

Data set 02

1938 Raytheon

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Heater Voltage

    643 V

    Heater Voltage 643 volts

  • Heater Current

    150 mA

    Heater Current 0.15 amp

  • Maximum Plate Supply Voltage

    135 V

    Maximum Plate Supply Voltage 135 volts

  • Maximum Target Voltage

    135 V

    Maximum Target Voltage 135 volts

  • Target Voltage

    135 V

    Target Voltage 135 volts

  • Plate Supply Voltage

    135 V

    Plate Supply Voltage 135 volts

  • Plate Resistor

    0.25 MΩ

    Plate Resistor 0.25 megohm

  • Target Current (Approximate)

    4.5 mA

    Target Current (Approximate) 4,5 ma,

  • Plate Current (Zero Bias )

    0.5 mA

    Plate Current (Zero Bias ) 0.5 ma

Data set 03

195X General Electric Essential Characteristics

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Target voltage maximum

    180 V

    TuningIndicator

  • Target voltage minimum

    125 V

    TuningIndicator

  • Plate voltage

    135 V

    TuningIndicator

  • Target voltage

    135 V

    TuningIndicator

  • Grid voltage

    -10 V

    Shadow0Degrees

  • Grid voltage

    0 V

    Shadow90Degrees

  • Plate current

    0.5 mA

    Shadow90Degrees

  • Target current

    2 mA

    TuningIndicator