Skip to main content

Power - Triode (over 1000V 100W) ·Triode

6960

Water-cooled industrial power triode for induction heating, dielectric heating, and plastic sealing. Rugged overload capability, roughly 6 kW plate dissipation, and about 10 kW published RF output suit continuous industrial generator service.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
12.6 V / 33 A

Description

Industrial water-cooled triode with large grid and plate overload capacity for induction/dielectric heating and plastic sealing.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
12.6 V
Nominal heater current
33 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Transconductance
0.015 S
Amplification factor
32
Max plate voltage
9500 V
Max plate dissipation
6000 W
Max cathode current
2 A

Published maximum ratings and general characteristics promoted from the supplied datasheet.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1953 Amperex

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Heater/Filament Voltage

    12.6 V

  • Heater/Filament Current

    33 A

  • Maximum Plate Voltage

    9500 V

  • Maximum Plate Dissipation

    6000 W

Characteristics

  • Transconductance

    15000 uS

  • Amplification Factor

    32

Data set 02

1963 Amperex Condensed

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Maximum plate dissipation

    6000 W

  • Typical plate voltage

    6500 V

    RF industrial service

  • Typical plate current

    2 A

    RF industrial service

  • Typical power output

    10000 W

    RF industrial service

  • Typical grid voltage

    -450 V

    RF industrial service

  • Typical grid current

    600 mA

    RF industrial service

  • Grid full-input power

    55 W

    RF industrial service

Characteristic

  • Grid-to-plate capacitance

    11 pF

  • Grid-to-filament capacitance

    16 pF

  • Plate-to-filament capacitance

    0.3 pF