Skip to main content

Voltage - Dual Triode (similar) ·Triode-Triode

6900

Rugged medium-mu twin triode specifically designed for high-current pulse service in missiles, aircraft, military, and industrial equipment, with exceptional shock capability and multiampere peak cathode-current ratings.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
2
Base
-
Socket code
B9A
Base pins
9
Nominal heater
6.3 V / 1 A

Description

Rugged medium-mu twin triode designed specifically for high-current pulse applications in missiles, aircraft, military, and industrial equipment. Electrical ratings, characteristics, operating data, and special environmental information were extracted from the supplied source.

Socket description

Small-button Noval 9-contact

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
B9A
Base pins
9
Nominal heater voltage
6.3 V
Nominal heater current
1 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

2 physical sections, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Transconductance
0.0115 S
Amplification factor
18.5
Max plate voltage
600 V
Max plate dissipation
4.25 W
Max cathode current
4.5 A

Published ratings and characteristics promoted from the approved datasheet.

Section 2

Triode

X-ray radiationInterelectrode capacitances
Transconductance
0.0115 S
Amplification factor
18.5
Max plate voltage
600 V
Max plate dissipation
4.25 W
Max cathode current
4.5 A

Second physical triode section; electrically identical twin section.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1961 Tung Sol

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Heater voltage

    6.3 V

    Nominal

  • Heater current

    1 A

    Nominal

  • Plate voltage

    600 V

    Published operating table; OperatingPoint1

  • Plate voltage

    120 V

    Published operating table; OperatingPoint1

  • Plate voltage

    500 V

    Published operating table; OperatingPoint1

  • Peak cathode current

    4.5 A

    Pulse

  • Pulse time

    10 us

    Pulse; BothSectionsParallel

  • Pulse repetition rate

    250 pps

    Pulse; BothSectionsParallel

Characteristic

  • Plate current

    36 mA

    Published operating table; OperatingPoint1

  • Transconductance

    11500 uS

    Published operating table; OperatingPoint1

Data set 02

1966 Tung Sol Electronic Tubes 4 of 4

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristics

  • LIMITS OF APPLIED VOLTAGE — published value 1

    6.3 V

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • LIMITS OF APPLIED VOLTAGE — published value 2

    0.3 V

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • PLATE VOLTAGE

    600 V

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • PEAK CATHODE CURRENT ®SEE CHART

    4.5 A

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • PLATE DISSIPATION PER PLATE

    4.25 W

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • GRID CIRCUIT RESISTANCE

    1 Mohm

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • AVERAGE WARM-UP TIME

    45 s

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • PLATE VOLTAGE

    120 V

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • GRID VOLTAGE

    2 V

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • TRANSCONDUCTANCE

    11500

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • AMPLIFICATION FACTOR

    18.5

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • PLATE VOLTAGE

    500 V

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • GRID PULSE ('egk)

    50 V

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • GRID VOLTAGE

    -100 V

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • PLATE BIAS VOLTAGE

    4.25 A

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • GRID CURRENT

    500 mA

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • PULSE TIME

    10

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • PULSE REPETITION RATE

    250

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • ALTITUDE ®SEE APPLICATION NOTE

    80000

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • IMPACT SHOCK

    500

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • Transconductance

    0.0115 A/V

    Promoted section value from the supplied datasheet.

  • Amplification factor

    18.5

    Promoted section value from the supplied datasheet.

Other

  • Maximum plate voltage

    600 V

    Promoted section value from the supplied datasheet.

  • Maximum plate dissipation

    4.25 W

    Promoted section value from the supplied datasheet.

  • Maximum cathode current

    4.5 A

    Promoted section value from the supplied datasheet.