Specialized - Thyratron ·Thyratron

6858

Large directly heated gas-and-mercury-vapor negative-control thyratron for grid-controlled rectifier service, providing very high peak-current capability.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
4BZ
Socket code
B9A
Base pins
4
Nominal heater
2.5 V / 21 A

Description

RCA 760/6858 is a large directly heated gas-and-mercury-vapor thyratron for grid-controlled rectifier service, with 1500-V peak anode ratings and very high peak current capability.

Socket description

Small-button Noval 9-contact

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
4BZ
Socket code
B9A
Base pins
4
Nominal heater voltage
2.5 V
Nominal heater current
21 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

4BZ - Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Thyratron

X-ray radiationInterelectrode capacitances
Max plate voltage
1500 V
Max cathode current
6 A
Rectifier forward voltage drop
12 V

Thyratron has no canonical SectionType; Other used. MaxCathodeCurrent uses published maximum average cathode current; peak/fault currents preserved separately.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1968 General Electric Co

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Other

  • Peak cathode current

    77 A

  • Average cathode current

    6 A

  • Fault cathode current

    770 A

  • Peak inverse anode voltage

    1500 V

Data set 02

1971 RCA HB3 Binder 2 of 7

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Other

  • Filament voltage

    2.5 V

    Nominal

  • Filament current

    21 A

    Nominal

  • Maximum deionization time

    1000 us

  • Maximum critical grid current

    10 uA

  • Peak forward anode voltage

    1500 V

  • Peak inverse anode voltage

    1500 V

  • Peak negative grid voltage before conduction

    500 V

  • Peak negative grid voltage during conduction

    10 V

  • Peak anode/cathode current

    77 A

  • Average anode/cathode current

    6.4 A

  • Fault current

    770 A

    Short-duration fault rating

  • Ambient or condensed-mercury operating temperature range

    -40 to +80 condensed-mercury operating range C

Characteristic

  • Minimum heating time prior to tube conduction

    60 s

  • Ionization time

    10 us

    Approximate

  • Anode voltage drop

    12 V

Capacitance

  • Grid-to-anode capacitance

    4 pF

    Approximate