Data set 01
1963 Amperex Condensed
Published operating points and test conditions from this source.
Triode
Other
Maximum plate dissipation
20000 W
Typical plate voltage
12500 V
RF industrial service
Typical plate current
3.5 A
RF industrial service
Typical power output
33000 W
RF industrial service
Typical grid voltage
-1200 V
RF industrial service
Typical grid current
250 mA
RF industrial service
Grid full-input power
22.5 W
RF industrial service
Characteristic
Grid-to-plate capacitance
26 pF
Grid-to-filament capacitance
25 pF
Plate-to-filament capacitance
1 pF