Skip to main content

Specialized - Thyratron ·Thyratron

676

Grid-controlled rectifier triode designed for continuous and welder-control switching service, providing controlled high-current conduction in industrial power equipment.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
IO
Base pins
-
Nominal heater
5 V / 10 A

Description

Grid-controlled rectifier triode for continuous and welder-control switching service.

Socket description

International Octal

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
IO
Base pins
-
Nominal heater voltage
5 V
Nominal heater current
10 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Thyratron

X-ray radiationInterelectrode capacitances
Max plate voltage
2500 V
Max cathode current
40 A
Rectifier peak inverse voltage
2500 V
Rectifier nominal output current
6.4 A
Rectifier peak forward current
40 A
Rectifier forward voltage drop
12 V

Thyratron section; peak/average current, inverse voltage, timing, and gas/mercury data retained as parameters.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1947 Westinghouse

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Other

  • HeaterCurrentNominal

    10 A

    Nominal

  • Maximum Peak Inverse Voltage

    2500 V

  • AverageOrDCOutputCurrent

    6.4 A

  • MaximumPeakForwardCurrent

    40 A

  • Peak Forward Anode Voltage

    2500 V

    Continuous service

Characteristic

  • Forward Voltage Drop

    12 V

  • Cathode Heating Time

    300 s

Data set 02

1971 RCA HB3 Binder 2 of 7

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Other

  • Peak forward anode voltage

    2500 V

  • Peak inverse anode voltage

    2500 V

  • Peak cathode/anode current

    40 A

  • Average cathode/anode current

    6.4 A

  • Fault or surge current

    200 A

    ShortDuration

  • Ambient temperature range

    40 to 90 C

  • Heater voltage

    5 V

  • Heater current

    10 A

  • Welder-control peak anode current

    77 A

    WelderControl

  • Welder-control average anode current

    2.5 A

    WelderControl

Characteristic

  • Ionization time

    10 us

    Approximate

  • Deionization time

    1000 us

    Approximate

  • Anode voltage drop

    12 V

    Conducting

Construction

  • Gas fill

    Mercury vapor

Capacitance

  • Grid-to-anode capacitance

    5 pF

    Approximate