Data set 01
1953 Amperex
Published operating points and test conditions from this source.
Rectifier
Other
Heater/Filament Voltage
5 V
Heater/Filament Current
11.5 A
Maximum Peak Inverse Voltage
25000 V
Rectifier - Half Wave ·Rectifier
Single-anode mercury-vapor half-wave rectifier with separate high-current and high-voltage ratings. Its heavy filament and low arc drop support multiampere industrial power conversion.
Single-anode mercury-vapor rectifier with separate high-current and high-voltage rating sets, up to 15 kV peak inverse voltage.
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Published maximum ratings and general characteristics promoted from the supplied datasheet.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Heater/Filament Voltage
5 V
Heater/Filament Current
11.5 A
Maximum Peak Inverse Voltage
25000 V
Data set 02
Published operating points and test conditions from this source.
Peak inverse voltage
2500 V
HighCurrent
Peak anode current
10 A
HighCurrent
Average anode current
5 A
HighCurrent
Overload current
200 A
HighCurrent
Peak inverse voltage
15000 V
HighVoltage
Peak anode current
12 A
HighVoltage
Average anode current
3 A
HighVoltage
Overload current
120 A
HighVoltage
Forward voltage drop
12 V
Warm-up time
60 s
Data set 03
Published operating points and test conditions from this source.
Fault anode current
120 A
0.1s max