Skip to main content

Rectifier - Half Wave ·Rectifier

6693

Single-anode mercury-vapor half-wave rectifier with separate high-current and high-voltage ratings. Its heavy filament and low arc drop support multiampere industrial power conversion.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
4
Nominal heater
5 V / 11.5 A

Description

Single-anode mercury-vapor rectifier with separate high-current and high-voltage rating sets, up to 15 kV peak inverse voltage.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
4
Nominal heater voltage
5 V
Nominal heater current
11.5 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Rectifier

X-ray radiationInterelectrode capacitances
Rectifier peak inverse voltage
15000 V
Rectifier nominal output current
3 A
Rectifier peak forward current
12 A
Rectifier forward voltage drop
12 V
Rectifier warm-up time
60 s

Published maximum ratings and general characteristics promoted from the supplied datasheet.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1953 Amperex

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • Heater/Filament Voltage

    5 V

  • Heater/Filament Current

    11.5 A

  • Maximum Peak Inverse Voltage

    25000 V

Data set 02

1963 Amperex Condensed

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • Peak inverse voltage

    2500 V

    HighCurrent

  • Peak anode current

    10 A

    HighCurrent

  • Average anode current

    5 A

    HighCurrent

  • Overload current

    200 A

    HighCurrent

  • Peak inverse voltage

    15000 V

    HighVoltage

  • Peak anode current

    12 A

    HighVoltage

  • Average anode current

    3 A

    HighVoltage

  • Overload current

    120 A

    HighVoltage

Characteristic

  • Forward voltage drop

    12 V

  • Warm-up time

    60 s

Data set 03

1971 English Electric Valve

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • Fault anode current

    120 A

    0.1s max