Tube cross-reference
6660 alternatives, equivalents, and replacements
Review exact electrical variations and directional substitutions recorded for the 6660 voltage pentode - remote cutoff (single). Compare core specifications and verify every restriction before using a replacement.
Replacement tubes for 6660
The following tubes are recorded as possible replacements for 6660. This direction does not establish that 6660 can replace them.
Voltage Pentode - Remote Cutoff (single)
The database records 5749 as a possible replacement for6660.
No special restrictions are recorded for this substitution.
| Specification | Original tube | Replacement |
|---|---|---|
| Tube type | Voltage Pentode - Remote Cutoff (single) | Voltage Pentode - Remote Cutoff (single) |
| Construction | Pentode | Pentode |
| Base | Not recorded | E7-1 |
| Socket | B7G | B7G |
| Base pins | 7 | 7 |
| Sections | 1 | 1 |
| Heater voltage | 6.3 V | 6.3 V |
| Heater current | 0.3 A | 0.3 A |
Voltage Pentode - Remote Cutoff (single)
The database records 6BA6 as a possible replacement for6660.
No special restrictions are recorded for this substitution.
| Specification | Original tube | Replacement |
|---|---|---|
| Tube type | Voltage Pentode - Remote Cutoff (single) | Voltage Pentode - Remote Cutoff (single) |
| Construction | Pentode | Pentode |
| Base | Not recorded | 7CC |
| Socket | B7G | B7G |
| Base pins | 7 | 7 |
| Sections | 1 | 1 |
| Heater voltage | 6.3 V | 6.3 V |
| Heater current | 0.3 A | 0.3 A |
Voltage Pentode - Remote Cutoff (single)
The database records 6BA6W as a possible replacement for6660.
No special restrictions are recorded for this substitution.
| Specification | Original tube | Replacement |
|---|---|---|
| Tube type | Voltage Pentode - Remote Cutoff (single) | Voltage Pentode - Remote Cutoff (single) |
| Construction | Pentode | Pentode |
| Base | Not recorded | Not recorded |
| Socket | B7G | B7G |
| Base pins | 7 | 7 |
| Sections | 1 | 1 |
| Heater voltage | 6.3 V | 6.3 V |
| Heater current | 0.3 A | 0.3 A |
Voltage Pentode - Remote Cutoff (single)
The database records EF93 as a possible replacement for6660.
No special restrictions are recorded for this substitution.
| Specification | Original tube | Replacement |
|---|---|---|
| Tube type | Voltage Pentode - Remote Cutoff (single) | Voltage Pentode - Remote Cutoff (single) |
| Construction | Pentode | Pentode |
| Base | Not recorded | B7G |
| Socket | B7G | B7G |
| Base pins | 7 | 7 |
| Sections | 1 | 1 |
| Heater voltage | 6.3 V | 6.3 V |
| Heater current | 0.3 A | 0.3 A |
Voltage Pentode - Remote Cutoff (single)
The database records W727 as a possible replacement for6660.
No special restrictions are recorded for this substitution.
| Specification | Original tube | Replacement |
|---|---|---|
| Tube type | Voltage Pentode - Remote Cutoff (single) | Voltage Pentode - Remote Cutoff (single) |
| Construction | Pentode | Pentode |
| Base | Not recorded | Not recorded |
| Socket | B7G | B7G |
| Base pins | 7 | 7 |
| Sections | 1 | 1 |
| Heater voltage | 6.3 V | 6.3 V |
| Heater current | 0.3 A | 0.3 A |
Where 6660 can be used as the replacement
In these recorded relationships, 6660 is the replacement tube. The listed original tubes are not automatically suitable as replacements for 6660.
Voltage Pentode - Remote Cutoff (single)
The database records 6660 as a possible replacement for6BA6.
No special restrictions are recorded for this substitution.
| Specification | 6660 replacement | Original tube |
|---|---|---|
| Tube type | Voltage Pentode - Remote Cutoff (single) | Voltage Pentode - Remote Cutoff (single) |
| Construction | Pentode | Pentode |
| Base | Not recorded | 7CC |
| Socket | B7G | B7G |
| Base pins | 7 | 7 |
| Sections | 1 | 1 |
| Heater voltage | 6.3 V | 6.3 V |
| Heater current | 0.3 A | 0.3 A |
Verify before substituting
Matching a base or heater voltage is not enough to prove that two tubes are interchangeable. Check pin connections, heater current, maximum ratings, bias requirements, warm-up behavior, and the equipment manufacturer’s service documentation before making a substitution.
View the complete 6660 specifications →