Skip to main content

Voltage Regulator ·VoltageRegulator

6627

High-reliability 0B2WA-family cold-cathode regulator providing approximately 108 V stabilization under severe environmental conditions.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
B7G
Base pins
7
Nominal heater
-

Description

High-reliability inert-gas cold-cathode miniature voltage regulator, co-designated 0B2WA, with stable voltage over life and severe environments. Electrical ratings, characteristics, operating data, and special environmental information were extracted from the supplied source.

Socket description

Miniature 7-contact

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
B7G
Base pins
7
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Voltage Regulator

X-ray radiationInterelectrode capacitances
Regulator voltage
108 V
Regulator minimum current
5 mA
Regulator maximum current
30 mA
Regulator starting voltage
130 V
Regulator maintaining voltage
108 V

Cold-cathode voltage regulator/reference discharge.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1961 Tung Sol

Published operating points and test conditions from this source.

SECTION 1

Voltage Regulator

Other

  • Regulator current minimum

    5 mA

  • Regulator current maximum

    30 mA

Data set 02

1966 Tung Sol Electronic Tubes 4 of 4

Published operating points and test conditions from this source.

SECTION 1

Voltage Regulator

Characteristics

  • MINIMUM DC CATHODE CURRENT

    5 mA

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • MINIMUM AMBIENT TEMPERATURE

    55 C

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • SHOCK IMPACT

    4

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • VIBRATION FATIGUE

    2.5

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • SHOCK:

    30

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • IONIZATION VOLTAGE (MAX.)

    130

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • TUBE VOLTAGE DROP ( 5. & 30. MA.) — published value 1

    105

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • TUBE VOLTAGE DROP ( 5. & 30. MA.) — published value 2

    111

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • REGULATION (5. TO 30. MA.) (MAX.)

    2.5

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • C HAN6E

    5 percent

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • VOLTAGE REPEATABILITY (MAX.)

    4 V

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • CHANGE

    3 mA

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • TUBE VOLTAGE DROP

    113 V

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • REGULATION (MAX.)

    3 V

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • IONIZATION VOLTAGE (MAX.)

    1

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • CHANGE IN TUBE VOLTAGE DROP FROM

    4 mA

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • TUBE VOLTAGE DROP

    116 V

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • TUBE

    1 V

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • TUBE — published value 1

    2 V

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • TUBE — published value 2

    30 V

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • REGULATION

    2.5 V

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • LEAKAGE CURRENT (Eb

    5 A

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • Regulator voltage

    108 V

    Promoted section value from the supplied datasheet.

  • Regulator maintaining voltage

    108 V

    Promoted section value from the supplied datasheet.

Other

  • MAXIMUM BULB TEMPERATURE

    150 C

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • MAXIMUM ALTITUDE — published value 1

    120 ft

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • MAXIMUM ALTITUDE — published value 2

    0 ft

    Published datasheet table value; multiple values on a source row represent separate limits or operating conditions.

  • Regulator minimum current

    5 mA

    Promoted section value from the supplied datasheet.

  • Regulator maximum current

    30 mA

    Promoted section value from the supplied datasheet.

  • Regulator starting/breakdown voltage

    130 V

    Promoted section value from the supplied datasheet.