Skip to main content

Specialized - Ignitron ·IgnitronPowerSwitch

6511

Water-cooled mercury-pool ignitron for frequency-changer resistance-welding control and industrial power-rectifier service.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
-

Description

Water-cooled mercury-pool ignitron for frequency-changer resistance-welding control and power-rectifier service.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

IgnitronPowerSwitch

X-ray radiationInterelectrode capacitances
Max cathode current
2016 A
Rectifier peak inverse voltage
1500 V
Rectifier nominal output current
70 A
Rectifier peak forward current
1500 A

Special-purpose data not represented by fixed promoted fields are preserved in TUBE_SECTION_PARAMETER. Ignitron/mercury-pool data semantically matching rectifier inverse-voltage and current fields were promoted; remaining grid, ignitor, auxiliary-anode, thermal, and fault ratings are parameters.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1950 General Electric Transmitting Types

Published operating points and test conditions from this source.

SECTION 1

IgnitronPowerSwitch

Other

  • Maximum Cathode Current

    2016 A

  • Maximum Average Anode Current

    2016 A

Data set 02

1968 General Electric Co

Published operating points and test conditions from this source.

SECTION 1

IgnitronPowerSwitch

Other

  • The GL

    6511 C

  • Ignitor Veltage Required to Fire

    200 V

  • Net Welght

    8.4 lb

  • Inlet Water Temperature maximum

    30 C

  • At No Load

    0.5 gal/min

  • Water Temperature Rise maximum

    6 C

  • Pregsure Drop at

    15 gal/min

  • Negatlive

    5 V

  • Peak

    100 A

  • Root Mean Square

    10 A

  • Average

    1 A

  • Maximum Averaging Time

    5 s

  • Maximum Voltage

    575 V