Skip to main content

Specialized - Ignitron ·IgnitronPowerSwitch

6504

Double-grid water-cooled mercury-pool ignitron designed for railroad-locomotive rectifier service.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
-

Description

The GL-6504 is a double-grid ignitron for railroad-locomotive rectifier service, with a coaxial cathode-current return for magnetic shielding and mercury-pool baffles that maintain ignitor contact during equipment sway.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

IgnitronPowerSwitch

X-ray radiationInterelectrode capacitances
Rectifier peak inverse voltage
4000 V
Rectifier nominal output current
350 A
Rectifier peak forward current
1250 A

Special-purpose data not represented by fixed promoted fields are preserved in TUBE_SECTION_PARAMETER. Ignitron/mercury-pool data semantically matching rectifier inverse-voltage and current fields were promoted; remaining grid, ignitor, auxiliary-anode, thermal, and fault ratings are parameters.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1968 General Electric Co

Published operating points and test conditions from this source.

SECTION 1

IgnitronPowerSwitch

Other

  • The GL

    6504 C

  • Inlet Water Temperature minimum

    30 C

  • Outlet Water Temperature maximum

    55 C

  • Water Temperature Rise maximum

    6.5 C

  • Pressure Drop at

    10 gal/min

  • Inverse

    4000 V

    Power-Rectifier Service %, Continuous Duty

  • Forward

    100 V

    Power-Rectifier Service %, Continuous Duty

  • Peak

    1250 A

    Power-Rectifier Service %, Continuous Duty

  • Maximum Inverse Voltage

    5 V

    Power-Rectifier Service %, Continuous Duty

  • Root Mean Square

    15 A

    Power-Rectifier Service %, Continuous Duty

  • Average

    2 A

    Power-Rectifier Service %, Continuous Duty

  • Maximum Averaging Time

    10 s

    Power-Rectifier Service %, Continuous Duty

  • Peak Inverse

    200 V

    Power-Rectifier Service %, Continuous Duty

  • Peak Inverse

    200 mA

    Power-Rectifier Service %, Continuous Duty

  • Peak Inverse Oy

    1 A

    Power-Rectifier Service %, Continuous Duty