Data set 01
1953 Amperex
Published operating points and test conditions from this source.
Rectifier
Characteristics
Coolant
Silicone oil
Other
Peak cathode current
8 A
Typical load voltage half-wave capacitor-input
5500 V
CapacitorInputFilter,OneTube
Typical load current half-wave capacitor-input
65 mA
CapacitorInputFilter,OneTube
Typical load voltage full-wave choke-input
4900 V
ChokeInputFilter,TwoTubes
Typical load current full-wave choke-input
130 mA