Skip to main content

Specialized - Switching Tube ·MicrowaveTRSwitch

6334

Dual band-pass TR microwave tube with common gas fill for X-band balanced duplexer service, providing paired receiver-protection switching paths.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
-

Description

Dual band-pass TR tube consisting essentially of two TR sections with a common gas fill for X-band balanced duplexer service.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

MicrowaveTRSwitch

X-ray radiationInterelectrode capacitances

No fixed ratings are recorded for this section.

Electrical ratings/characteristics audited; additional published numeric data retained in parameter table.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1950 Sylvania

Published operating points and test conditions from this source.

SECTION 1

MicrowaveTRSwitch

Characteristic

  • Frequency range minimum

    8490 MHz

    Published datasheet value

  • Frequency range maximum

    9578 MHz

    Published datasheet value

  • Ignitor open-circuit voltage

    -700 V

    Published datasheet value

Other

  • Flat leakage power maximum

    20 mW

    40 kW transmitter power

Data set 02

1972 Thomson CSF

Published operating points and test conditions from this source.

SECTION 1

MicrowaveTRSwitch

Other

  • pour un courant de [1]

    100 A

    pour un courant de 100 pA -200 & =375 V

  • pour un courant de [2]

    -200 A

    pour un courant de 100 pA -200 & =375 V

  • pour un courant de [3]

    375 A

    pour un courant de 100 pA -200 & =375 V

  • par impulsion de Ipus, maximum ceee

    15

    par impulsion de Ipus, maximum ceee 0,15 erg

  • Tension d'alimentation minimale des Electrodes en circuit v (

    2 V

    Tension d'alimentation minimale des Electrodes en circuit v (2)

  • tation doit [1]

    8 A

    tation doit 8tre faite 3 courant constant & 1'aide de source

  • tation doit [2]

    3 A

    tation doit 8tre faite 3 courant constant & 1'aide de source

  • tation doit [3]

    1 A

    tation doit 8tre faite 3 courant constant & 1'aide de source