Skip to main content

Specialized - Thyratron ·Thyratron

632B

Gas-filled grid-controlled thyratron for controlled rectifier, relay, motor-control, industrial switching, or pulse service.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
IO
Base pins
8
Nominal heater
5 V / 5 A

Description

Mercury-vapor tetrode thyratron for ignitor firing and grid-controlled rectifier service.

Socket description

International Octal

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
IO
Base pins
8
Nominal heater voltage
5 V
Nominal heater current
5 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Thyratron

X-ray radiationInterelectrode capacitances
Max plate voltage
1500 V
Max cathode current
30 A
Rectifier forward voltage drop
12 V

Thyratron section; peak/average current, inverse voltage, timing, and gas/mercury data retained as parameters.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1963 Amperex Condensed

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Characteristic

  • Filament heating time

    300 s

    MercuryVaporThyratron

  • Tube voltage drop

    12 V

    MercuryVaporThyratron

  • Deionization time

    1000 µs

    MercuryVaporThyratron

Other

  • Peak forward voltage maximum

    1500 V

    MercuryVaporThyratron

  • Peak inverse voltage maximum

    1500 V

    MercuryVaporThyratron

  • Peak anode current maximum

    30 A

    MercuryVaporThyratron

  • Average anode current maximum

    5 A

    MercuryVaporThyratron

  • Maximum grid voltage

    -300 V

    MercuryVaporThyratron

  • Recommended mercury temperature range

    +45 to +50 °C

    MercuryVaporThyratron

  • Application

    Ignitor firing and grid-controlled rectifier service

    Section1

Data set 02

1971 RCA HB3 Binder 2 of 7

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Other

  • Peak forward anode voltage

    1500 V

  • Peak inverse anode voltage

    1500 V

  • Peak cathode/anode current

    30 A

  • Average cathode/anode current

    2.5 A

  • Fault or surge current

    150 A

    ShortDuration

  • Ambient temperature range

    40 to 80 C condensed-mercury

  • Heater voltage

    5 V

  • Heater current

    5 A

  • Peak grid No.2 voltage

    -300 V

  • Peak grid No.1 voltage

    -1000 V

Characteristic

  • Ionization time

    10 us

    Approximate

  • Deionization time

    1000 us

    Approximate

  • Anode voltage drop

    12 V

    Conducting

  • Minimum heating time

    5 min

    BeforeConduction

Construction

  • Gas fill

    Mercury vapor

Capacitance

  • Grid-to-anode capacitance

    0.04 pF

    Approximate

  • Grid No.2-to-anode capacitance

    3 pF