Skip to main content

Voltage - Dual Triode (similar) ·Triode-Triode

6168

Medium-mu twin triode with series/parallel heater connection, intended for Class-A amplifier service and providing two similar sections with moderate gain.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
2
Base
9A
Socket code
B9A
Base pins
9
Nominal heater
12.6 V / 300 mA

Description

Medium-mu twin triode with series/parallel heater connection and Class A amplifier data.

Socket description

Small-button Noval 9-contact

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
9A
Socket code
B9A
Base pins
9
Nominal heater voltage
12.6 V
Nominal heater current
300 mA
Parallel heater voltage
6.3 V
Parallel heater current
600 mA
Series capable
Yes

9A - Terminal pinout

Electrical assignments shared by every tube using this base designation.

TerminalSectionConnectionEvidence
PIN12PBP — Plate (Anode)

EIA transcription; manufacturer confirmation pending

Unverified

EIA Base Connections, printed page 130, 9A

PIN22G1BG1 — Control Grid

EIA transcription; manufacturer confirmation pending

Unverified

EIA Base Connections, printed page 130, 9A

PIN32KBK — Cathode

EIA transcription; manufacturer confirmation pending

Unverified

EIA Base Connections, printed page 130, 9A

PIN4H—H — Heater

EIA transcription; manufacturer confirmation pending

Unverified

EIA Base Connections, printed page 130, 9A

PIN5H—H — Heater

EIA transcription; manufacturer confirmation pending

Unverified

EIA Base Connections, printed page 130, 9A

PIN61PAP — Plate (Anode)

EIA transcription; manufacturer confirmation pending

Unverified

EIA Base Connections, printed page 130, 9A

PIN71G1AG1 — Control Grid

EIA transcription; manufacturer confirmation pending

Unverified

EIA Base Connections, printed page 130, 9A

PIN81KAK — Cathode

EIA transcription; manufacturer confirmation pending

Unverified

EIA Base Connections, printed page 130, 9A

PIN9HCT—HCT — Heater Center Tap

EIA transcription; manufacturer confirmation pending

Unverified

EIA Base Connections, printed page 130, 9A

Section ratings

2 physical sections, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Plate resistance
14000 Ω
Transconductance
0.0023 S
Amplification factor
32
Max plate voltage
300 V

One of two electrically similar medium-mu triodes; identical-section compression applied.

Section 2

Triode

X-ray radiationInterelectrode capacitances
Plate resistance
14000 Ω
Transconductance
0.0023 S
Amplification factor
32

Second physical triode restored.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

195X General Electric Essential Characteristics

Published operating points and test conditions from this source.

SECTION 1

Triode

Capacitance

  • Input capacitance

    2.3 pF

  • Grid-to-plate capacitance

    2.1 pF

Other

  • Plate voltage

    250 V

    ClassA

  • Grid voltage

    -6 V

    ClassA

  • Plate current

    4.6 mA

    ClassA

Characteristic

  • Plate resistance

    14000 ohm

  • Transconductance

    2300 uS

  • Amplification factor

    32