Data set 01
1950 Sylvania
Published operating points and test conditions from this source.
Pentode
Characteristic
Heater Voltage
6.3 V
Heater Current
600 mA
Plate Current
34 mA
PlateVoltage=150V
Voltage Pentode - Sharp Cutoff (single) ·Pentode
Lock-In sharp-cutoff pentode amplifier designed for electronic-computer service. Its fixed-gain signal-amplifier function is combined with Lock-In construction for reliable operation in early electronic computing equipment.
Lock-in sharp-cutoff pentode amplifier for electronic-computer service.
Loctal 8-contact
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
| Terminal | Section | Connection | Evidence |
|---|---|---|---|
| PIN1H | — | H — Heater EIA source transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 129, 8V |
| PIN2P | A | P — Plate (Anode) EIA source transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 129, 8V |
| PIN3G2 | A | G2 — Screen Grid EIA source transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 129, 8V |
| PIN4G3 | A | G3 — Suppressor Grid EIA source transcription; manufacturer confirmation pending | Unverified EIA Base Connections, printed page 129, 8V |
| PIN5IS | A | IS — Internal Screen EIA chart transcription; manufacturer verification pending | Unverified EIA Base Connections, printed page 129, 8V |
| PIN6G1 | A | G1 — Control Grid EIA chart transcription; manufacturer verification pending | Unverified EIA Base Connections, printed page 129, 8V |
| PIN7K | A | K — Cathode EIA chart transcription; manufacturer verification pending | Unverified EIA Base Connections, printed page 129, 8V |
| PIN8H | — | H — Heater EIA chart transcription; manufacturer verification pending | Unverified EIA Base Connections, printed page 129, 8V |
1 physical section, each with unique specifications.
Section 1
Sharp-cutoff pentode; pulse-amplifier conditions published.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Heater Voltage
6.3 V
Heater Current
600 mA
Plate Current
34 mA
PlateVoltage=150V
Data set 02
Published operating points and test conditions from this source.
Input capacitance
14 pF
Output capacitance
7.5 pF
Grid-to-plate capacitance
0.06 pF
Plate voltage
150 V
PulseAmplifier
Screen-grid voltage
100 V
PulseAmplifier
Grid voltage
0 V
PulseAmplifier
Plate current
34 mA
PulseAmplifier
Screen-grid current
8 mA
PulseAmplifier
Plate resistance
100000 ohm
PulseAmplifier