Skip to main content

Specialized - Thyratron ·Thyratron

6130

Hydrogen thyratron for high-repetition-rate, high-peak-current pulsing, including high-altitude and zero-bias-control operation.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
B9A
Base pins
9
Nominal heater
6.3 V / 2.25 A

Description

Hydrogen thyratron for high-repetition-rate pulsing at high peak current, including high-altitude operation and zero-bias control.

Socket description

Small-button Noval 9-contact

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
B9A
Base pins
9
Nominal heater voltage
6.3 V
Nominal heater current
2.25 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Thyratron

X-ray radiationInterelectrode capacitances
Max plate voltage
3000 V
Max cathode current
35 A
Rectifier forward voltage drop
150 V

Thyratron pulse ratings promoted where semantically compatible; trigger, delay, jitter, reservoir and current-rate data retained as parameters.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1950 General Electric Transmitting Types

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Other

  • Maximum Plate Voltage

    25000 V

  • Maximum Cathode Current

    325 A

  • Peak Anode Current

    325 A

  • Maximum Repetition Rate

    4000 pps

Characteristic

  • Altitude Capability

    50000 ft

Data set 02

1962 ITT

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Characteristic

  • Heater current

    2 A to 2.5 A

  • Heater voltage nominal

    6.3 V

Other

  • Minimum heating time

    2 min

  • Maximum peak forward anode voltage

    3000 V

  • Maximum peak inverse anode voltage

    3000 V

  • Maximum peak anode current

    35 A

  • Maximum average anode current

    45 mA

  • Maximum RMS anode current

    1.25 A

  • Maximum anode current rate of rise

    750 A/us

  • Maximum peak inverse trigger voltage

    200 V

  • Maximum anode delay time

    0.6 us

  • Maximum anode delay-time drift

    0.15 us

  • Initial maximum time jitter

    0.02 us

Data set 03

1971 RCA HB3 Binder 2 of 7

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Other

  • Peak forward anode voltage

    3000 V

  • Peak inverse anode voltage

    1500 V

  • Peak cathode/anode current

    35 A

  • Average cathode/anode current

    45 mA

  • Ambient temperature range

    -50 to +90 C

  • Heater voltage

    6.3 V

  • Heater current

    2.3 A

  • Minimum DC anode-supply voltage

    800 V

    PulseModulator

  • Peak positive grid pulse

    175 V

    PulseModulator

  • Current rate of rise

    750 A/us

    PulseModulator

  • Pulse duration

    6 us

    PulseModulator

  • Peak power output

    43 kW

    TypicalPulseOperation

Characteristic

  • Ionization time

    0.6 us

    Approximate

  • Deionization time

    25 us

    Approximate

  • Anode voltage drop

    150 V

    Conducting

  • Minimum heating time

    2 min

    BeforeConduction

  • Maximum jitter

    0.06 us

Construction

  • Gas fill

    Hydrogen

Capacitance

  • Grid-to-anode capacitance

    3.9 pF

    Approximate

  • Grid-to-cathode capacitance

    8.6 pF

    Approximate