Iatended for applications at altitudes up to 60,000 feet where — published value 1
60 ft
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Iatended for applications at altitudes up to 60,000 feet where — published value 2
0 ft
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Voltage
6.3 V
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Current
300 mA
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Grid to plate (Each unit) — published value 1
1.5
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Grid to plate (Each unit) — published value 2
1.4
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Plate—Supply Voltage
100 V
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Plate Resistance (Approx )
4000 ohm
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Transconductance
5000 uS
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Plate Current
8.5 mA
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Lead 1 —Plate of — published value 1
1
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Lead 1 —Plate of — published value 2
5
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Lead 2 —Grid of — published value 1
2
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Lead 2 —Grid of — published value 2
6
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Unit No.2
7
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Lead 3 —Heater
3
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Lead 4 —Cathode of — published value 1
4
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Lead 4 —Cathode of — published value 2
8
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
For operation at altitudes uq to 60,000 feet — published value 1
60 ft
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
For operation at altitudes uq to 60,000 feet — published value 2
0 ft
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Positive bias value
0 V
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Negative bias value
55 V
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Heater negative with respect to cathode
200 V
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Heater Current — published value 1
1 mA
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Heater Current — published value 2
280 mA
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Heater Current — published value 3
320 mA
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Grid to plate — published value 1
2
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Grid to plate — published value 2
1.2
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Grid to plate — published value 3
1.8
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.
Grid to cathode and heater — published value 1
2
Published datasheet value; multiple values on a source row represent separate source-table conditions or limits.