Data set 01
1961 Tung Sol
Published operating points and test conditions from this source.
Beam Power
Other
AltitudeMaximum
60000 ft
EnvelopeTemperatureMaximum
300 C
Power Output
4.5 W
Power - Beam (NOT sweep) ·BeamPower
Hard-glass beam-power pentode designed for mobile equipment, high ambient temperatures, and severe vibration, shock, and acceleration.
The 6094 is a hard-glass beam-power pentode designed for mobile equipment, high ambient temperatures and severe vibration, shock and acceleration.
Small-button Noval 9-contact
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Published characteristics and ratings promoted where clearly recoverable from source.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
AltitudeMaximum
60000 ft
EnvelopeTemperatureMaximum
300 C
Power Output
4.5 W
Data set 02
Published operating points and test conditions from this source.
Grid 1 to plate capacitance
1.45 pF
WholeTube
Input capacitance
8.5 pF
WholeTube
Output capacitance
5.3 pF
WholeTube
Maximum plate voltage
275 V
WholeTube
Maximum grid 2 voltage
275 V
WholeTube
Maximum plate dissipation
12.5 W
WholeTube
Maximum grid 2 dissipation
2 W
WholeTube
Maximum cathode current
75 mA
WholeTube
Maximum heater-cathode voltage
450 V
WholeTube
Plate voltage
250 V
TypicalOperation
Grid 2 voltage
250 V
TypicalOperation
Grid 1 voltage
-12.5 V
TypicalOperation
Plate current
45 mA
TypicalOperation
Grid 2 current
3.5 mA
TypicalOperation
Transconductance
4100 uS
TypicalOperation
Grid 1 signal voltage
8.8 Vrms
TypicalOperation
Load resistance
5000 ohm
TypicalOperation
Power output
4.5 W
TypicalOperation
Data set 03
Published operating points and test conditions from this source.
Heater Voltage
9 V
Published datasheet value; see source context.
Plate Voltage
300 V
Published datasheet value; see source context.
Cathode Current
80000 mA
Published datasheet value; see source context.
Heater Current
600 mA
Published datasheet value; see source context.
Plate Current
0.6 mA
Published datasheet value; see source context.
Transconductance
5200 µS
Published datasheet value; see source context.