Skip to main content

Power - Triode (over 1000V 100W) ·Triode

6077

Very-high-power directly heated triode with an exceptionally heavy filament. Available source material does not establish a narrower functional application confidently.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
17.5 V / 196 A

Description

6077 is a Triode device. Water-cooled very-high-power RF triode for amplifier, oscillator, and modulator service; plate dissipation 45 kW in Class C and up to 100 kW in Class-B RF operation.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
17.5 V
Nominal heater current
196 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Amplification factor
27
Max plate voltage
12000 V
Max plate dissipation
100000 W
Max cathode current
120 A

Published promoted ratings/characteristics captured where applicable; additional source values preserved in parameter rows.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1953 Amperex

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Maximum frequency at full ratings

    15 MHz

  • Reduced-rating frequency

    30 MHz

  • Filament starting current maximum

    420 A

  • Peak cathode current maximum

    120 A

Data set 02

1958 Amperex Industrial

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristic

  • Amplification factor

    27

  • Maximum frequency

    30 MHz

  • Grid-to-plate capacitance

    6 pF

  • Grid-to-filament capacitance

    116 pF

  • Plate-to-filament capacitance

    3.4 pF

Other

  • Maximum plate dissipation

    100000 W

  • Plate voltage

    12000 V

    ClassC

  • Plate current

    12 A

    ClassC

  • Power output

    108000 W

    ClassC

  • Grid voltage

    -1000 V

    ClassC

  • Grid current

    2.25 A

    ClassC

Data set 03

1963 Amperex Condensed

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Plate voltage

    12000 V

    RFAmplifierOrOscillator; ClassC

  • Plate current

    12 A

    RFAmplifierOrOscillator; ClassC

  • RF output power

    108 kW

    RFAmplifierOrOscillator; ClassC

  • Grid voltage

    -1000 V

    RFAmplifierOrOscillator; ClassC

  • Grid current

    2.25 A

    RFAmplifierOrOscillator; ClassC

  • Maximum frequency at full input rating

    15 MHz

  • Maximum plate dissipation Class B RF

    100 kW

    ClassB; RF

Capacitance

  • Grid-to-plate capacitance

    86 pF

  • Grid-to-filament capacitance

    116 pF

  • Plate-to-filament capacitance

    3.4 pF