Skip to main content

Specialized - Thyratron ·Thyratron

6011

Gas-filled grid-controlled thyratron for controlled rectifier, relay, motor-control, industrial switching, or pulse service.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
B9A
Base pins
9
Nominal heater
2.5 V / 9 A

Description

Gas and mercury-vapor negative-control triode thyratron, co-designated with type 710.

Socket description

Small-button Noval 9-contact

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
B9A
Base pins
9
Nominal heater voltage
2.5 V
Nominal heater current
9 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Thyratron

X-ray radiationInterelectrode capacitances
Max plate voltage
1500 V
Max cathode current
2.5 A
Rectifier forward voltage drop
10 V

Thyratron section; published switching/rating data retained below.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1956 National Electronics Industrial Tubes

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Other

  • Maximum peak inverse voltage

    1500 V

    Published datasheet value

  • Maximum peak forward voltage

    1500 V

    Published datasheet value

  • Maximum DC output current

    2.5 A

    Published datasheet value

  • Maximum instantaneous output current

    30 A

    Published datasheet value

  • Maximum AC short-circuit current

    250 A

    Published datasheet value

Characteristics

  • Heating time

    20 s

    Published datasheet value

  • Typical arc drop

    10 V

    At stated peak current

  • Ionization time

    10 us

    Approximate

  • Deionization time

    1000 us

    Approximate

  • Anode-grid capacitance

    2 pF

    Published capacitance

  • Grid-cathode capacitance

    12 pF

    Published capacitance

Data set 02

1971 RCA HB3 Binder 2 of 7

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Other

  • Peak forward anode voltage

    1500 V

  • Peak inverse anode voltage

    1500 V

  • Peak cathode/anode current

    30 A

  • Average cathode/anode current

    2.5 A

  • Fault or surge current

    250 A

    ShortDuration

  • Ambient temperature range

    -40 to +90 C

  • Filament voltage

    2.5 V

  • Filament current

    9 A

Characteristic

  • Ionization time

    10 us

    Approximate

  • Deionization time

    1000 us

    Approximate

  • Anode voltage drop

    10 V

    Conducting

  • Minimum heating time

    20 s

    BeforeConduction

  • Condensed-mercury temperature rise no load

    25 degC

  • Condensed-mercury temperature rise full load

    30 degC

Construction

  • Gas fill

    Gas and mercury vapor

Capacitance

  • Grid-to-anode capacitance

    2 pF

    Approximate

  • Grid-to-cathode capacitance

    12 pF

    Approximate