Skip to main content

Rectifier - Full Wave ·Rectifier-Rectifier

5Y3G

Directly heated full-wave high-vacuum rectifier for general receiver and amplifier power supplies. Its five-volt filament and moderate output capability made it a common B-plus supply rectifier.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
2
Base
5T
Socket code
IO
Base pins
-
Nominal heater
5 V / 2 A

Description

Full-wave directly heated high-vacuum rectifier.

Socket description

International Octal

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
5T
Socket code
IO
Base pins
-
Nominal heater voltage
5 V
Nominal heater current
2 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

5T - Terminal pinout

Electrical assignments shared by every tube using this base designation.

TerminalSectionConnectionEvidence
PIN1ISAIS — Internal Screen

EIA chart transcription; manufacturer corroboration pending

Unverified

EIA Base Connections, printed page 127, 5T

PIN2F—F — Filament

EIA chart transcription; manufacturer corroboration pending

Unverified

EIA Base Connections, printed page 127, 5T

PIN4P1AP — Plate (Anode)

EIA chart transcription; manufacturer corroboration pending; preserve source designation P1

Unverified

EIA Base Connections, printed page 127, 5T

PIN6P2AP — Plate (Anode)

EIA chart transcription; manufacturer corroboration pending; preserve source designation P2

Unverified

EIA Base Connections, printed page 127, 5T

PIN8F—F — Filament

EIA chart transcription; manufacturer corroboration pending

Unverified

EIA Base Connections, printed page 127, 5T

Section ratings

2 physical sections, each with unique specifications.

Section 1

Rectifier

X-ray radiationInterelectrode capacitances
Rectifier peak inverse voltage
1400 V
Rectifier nominal output current
125 mA
Rectifier peak forward current
375 mA
Rectifier forward voltage drop
30 V

Published full-wave rectifier ratings promoted from the printed chart; supply-voltage and voltage-drop test conditions retained as parameters.

Section 2

Rectifier

X-ray radiationInterelectrode capacitances
Rectifier peak inverse voltage
1400 V
Rectifier nominal output current
125 mA
Rectifier peak forward current
375 mA
Rectifier forward voltage drop
30 V

Second physical rectifier section; electrical properties populated from corresponding identical section.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1937 Raytheon Radio Receiving Tubes

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • Heater/filament voltage

    5 V

    Section1

  • Heater/filament current

    2 A

    Section1

  • RMS AC voltage per plate maximum

    350 V

    FullWave

  • Peak inverse voltage maximum

    1400 V

    FullWave

  • DC output current maximum

    125 mA

    FullWave

Data set 02

1948 Brimar Radio Valve Manual

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • Peak Inverse Voltage

    1400 V

  • Peak Current per Anode

    375 mA

  • Rectified Current

    125 mA

  • RMS Input per Anode

    500 V

  • RMS Input per Anode

    350 V

    CapacitorInputFilter

  • Rectified Current

    125 mA

    CapacitorInputFilter

  • Reservoir Capacitor

    32 uF

    CapacitorInputFilter

  • RMS Input per Anode

    500 V

    ChokeInputFilter

  • Rectified Current

    125 mA

    ChokeInputFilter

  • Input Choke Inductance

    5 H

    ChokeInputFilter

Data set 03

195X General Electric Essential Characteristics

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • Filament/heater voltage

    5 V

    Published condensed-characteristics chart

  • Filament/heater current

    2 A

    Published condensed-characteristics chart

  • DC output current maximum

    125 mA

    FullWave

  • Peak inverse voltage maximum

    1400 V

    FullWave

  • RMS supply voltage per plate maximum

    350 V

    FullWave

  • Peak current per plate maximum

    375 mA

    FullWave

Characteristic

  • Tube voltage drop

    30 V

    At 125 mA DC