Data set 01
1966 Tung Sol Electronic Tubes 1 of 4
Published operating points and test conditions from this source.
Rectifier
Other
Maximum peak inverse plate voltage
1550 V
Maximum RMS AC plate supply voltage per plate
550 V RMS
Maximum steady-state peak plate current per plate
1.4 A
Maximum transient peak plate current per plate
4.6 A
Maximum DC output current
415 mA
CapacitorInputFilter; 470V AC
AC plate supply voltage per plate
300 V RMS
CapacitorInputFilter
Filter input capacitance
40 uF
CapacitorInputFilter
DC output current
380 mA
CapacitorInputFilter; 300V AC
DC output voltage
300 V
CapacitorInputFilter; 300V AC
AC plate supply voltage per plate
425 V RMS
CapacitorInputFilter
DC output current
350 mA
CapacitorInputFilter; 425V AC
DC output voltage
440 V
CapacitorInputFilter; 425V AC
Filter input choke
10 H
ChokeInputFilter
DC output current
350 mA
ChokeInputFilter
DC output voltage
390 V
ChokeInputFilter
Characteristic
Tube voltage drop at 350 mA per plate
42 V
Rectifier
Other
Maximum peak inverse plate voltage
1550 V
Maximum RMS AC plate supply voltage per plate
550 V RMS
Maximum steady-state peak plate current per plate
1.4 A