Data set 01
1961 Tung Sol
Published operating points and test conditions from this source.
Rectifier
Other
Heater voltage
5 V
Heater current
2 A
Rectifier
Other
Heater voltage
5 V
Heater current
2 A
Rectifier - Full Wave ·Rectifier-Rectifier
Ruggedized directly heated full-wave high-vacuum rectifier for reliable high-voltage and high-altitude power-supply service, providing approximately 275 mA DC output with high inverse-voltage capability.
Rugged directly heated high-vacuum full-wave rectifier with a shock-mounted skirted base, intended for reliable high-voltage power-supply service and high-altitude operation.
International Octal
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
2 physical sections, each with unique specifications.
Section 1
Representative row for repeated electrically identical sections.
Section 2
Second physical rectifier section; promoted electrical properties populated from identical section.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Heater voltage
5 V
Heater current
2 A
Heater voltage
5 V
Heater current
2 A
Data set 02
Published operating points and test conditions from this source.
Heater voltage
5 V
Heater current
2 A
AC plate voltage per plate
900 V
ChokeInputFilter
Input choke
10 H
ChokeInputFilter
DC output current
165 mA
ChokeInputFilter
DC output voltage full load
840 V
ChokeInputFilter
AC plate voltage per plate
700 V
CapacitorInputFilter
Input capacitor
4 uF
CapacitorInputFilter
Minimum plate supply impedance per plate
100 ohm
CapacitorInputFilter
DC output current
275 mA
CapacitorInputFilter
DC output voltage full load
730 V
CapacitorInputFilter
Maximum peak inverse voltage
3050 V
Nominal DC output current
275 mA
Maximum peak forward current
700 mA
Warmup time
10 s
Heater voltage
5 V